Hi there, I actually made the changes on my server to reflect what Alex has and still the same results, the VNC server connection gets dumped when a second connection is attempted.
Tracy ---------- Original Text ---------- From: "Alex Angelopoulos" <[EMAIL PROTECTED]>, on 2002/01/23 1:23 PM: To: iSMTP@HQNT11@Servers[<[EMAIL PROTECTED]>],Tracy Millar@MIS SIG@IDRC CRDI COMPARISON OF REGISTRY VALUES (SUMMARY NOTE: Tracy is having an issue with having a VNC server connection dumped when someone else connects to the same system. She has, as can be seen, created the ConnectPriority DWORD with a value of "2", restarted the server, etc.) Just a quick note - I am going to try checking this out on my system, but I did a quick check on the registry values. The only differences in our setups were the following values: "AutoPortSelect" - mine was 1 as opposed to your "0" - but see next item "PortNumber" - you had this which I didn't, but yours is set to 0x170c(5900), the default "IdleTimeout" - Yours is "0"; I didn't have this setting "ConnectPriority" - I had this set to "1"from checking your problem last week, and I *did* connect successfully from 2 locations simultaneously. ---- Original Message ----- From: "Tracy Millar" <[EMAIL PROTECTED]> To: <[EMAIL PROTECTED]> Sent: Wednesday/2002 January 23 12:38 Subject: Re: ConnectPriority - Registry info : As requested, here are the registry files as per below... : : ********* : REGEDIT4 : : [HKEY_CURRENT_USER\Software\ORL\WinVNC3] : "SocketConnect"=dword:00000001 : "AutoPortSelect"=dword:00000000 Mine is 1; obviously you have a custom port setting : "PortNumber"=dword:0000170c Which is here...and is set to 5900 manually : "InputsEnabled"=dword:00000001 : "LocalInputsDisabled"=dword:00000000 : "IdleTimeout"=dword:00000000 I don't even have this : "QuerySetting"=dword:00000002 : "QueryTimeout"=dword:0000000a : "PollUnderCursor"=dword:00000000 : "PollForeground"=dword:00000001 : "PollFullScreen"=dword:00000000 : "OnlyPollConsole"=dword:00000001 : "OnlyPollOnEvent"=dword:00000000 : "ConnectPriority"=dword:00000002 I set this to "1" for a test earlier and was able to do 2 simultaneous connects : ******************* : REGEDIT4 : : [HKEY_LOCAL_MACHINE\SOFTWARE\ORL\WinVNC3\Default] : "SocketConnect"=dword:00000001 : "AutoPortSelect"=dword:00000000 Didn't have this here : "PortNumber"=dword:0000170c Again, didn't have this : "InputsEnabled"=dword:00000001 : "LocalInputsDisabled"=dword:00000000 : "IdleTimeout"=dword:00000000 Didn't have this here either : "QuerySetting"=dword:00000002 : "QueryTimeout"=dword:0000000a : "PollUnderCursor"=dword:00000000 : "PollForeground"=dword:00000001 : "PollFullScreen"=dword:00000000 : "OnlyPollConsole"=dword:00000001 : "OnlyPollOnEvent"=dword:00000000 : "ConnectPriority"=dword:00000002 Again, had a test setting of 1 : Attachment(s): : HKCU.REG : HKLM.REG --------------------------------------------------------------------- To unsubscribe, mail [EMAIL PROTECTED] with the line: 'unsubscribe vnc-list' in the message BODY See also: http://www.uk.research.att.com/vnc/intouch.html --------------------------------------------------------------------- --------------------------------------------------------------------- To unsubscribe, mail [EMAIL PROTECTED] with the line: 'unsubscribe vnc-list' in the message BODY See also: http://www.uk.research.att.com/vnc/intouch.html ---------------------------------------------------------------------