Item solved.

We have unmount the brick. Format and Mount  at the same Mount point.

Add the engine dir and chown 036:036.

In ovirt on that brick we have click ob reset brick and now all 6 brick are in 
sync. 

Br
Marcel

Am 19. April 2021 14:16:48 MESZ schrieb Marcel d'Heureuse <[email protected]>:
>Hi Guys,
>
>We hat a planned power outage and we have stopped all VMS and try to
>keep
>the servers alive as long as possible.
>
>Some Servers made a Reboot by itself but the IPMI interface was not
>reachable for the engine. The some hosts have made a restart.
>
>Now all systems running and all 180 VMs too. But one Brick of the
>hosted
>engine didn't come up.
>
>Did you have an idea. Please find attached some screenshots.
>
>Our Hosted Engine has 6 bricks on 6 different Servers.
>
>A restart of the Host didn't work. The Server Restart of glusterd
>didn't
>work.
>
>I hope you have some more Ideas?
>
>Thanks
>Br
>Marcel
_______________________________________________
Users mailing list -- [email protected]
To unsubscribe send an email to [email protected]
Privacy Statement: https://www.ovirt.org/privacy-policy.html
oVirt Code of Conduct: 
https://www.ovirt.org/community/about/community-guidelines/
List Archives: 
https://lists.ovirt.org/archives/list/[email protected]/message/GHO5GLQVITB5WUXEKMMXFWUCFMHFQQ2E/

Reply via email to