But actually, it didn't work well. After main SPM host went down I see this
2017-04-17 05:23:15,554Z ERROR [org.ovirt.engine.core.vdsbroker.irsbroker.IrsProxy] (DefaultQuartzScheduler5) [4dcc033d-26bf-49bb-bfaa-03a970dbbec1] SPM Init: could not find reported vds or not up - pool: 'STG' vds_spm_id: '1' 2017-04-17 05:23:15,567Z INFO [org.ovirt.engine.core.vdsbroker.irsbroker.IrsProxy] (DefaultQuartzScheduler5) [4dcc033d-26bf-49bb-bfaa-03a970dbbec1] SPM selection - vds seems as spm 'tank5' 2017-04-17 05:23:15,567Z WARN [org.ovirt.engine.core.vdsbroker.irsbroker.IrsProxy] (DefaultQuartzScheduler5) [4dcc033d-26bf-49bb-bfaa-03a970dbbec1] spm vds is non responsive, stopping spm selection. So that means only if BMC is up it's possible to automatically switch SPM host? Thanks On Sun, Apr 16, 2017 at 8:29 PM, Konstantin Raskoshnyi <[email protected]> wrote: > Oh, fence agent works fine if I select ilo4, > Thank you for your help! > > On Sun, Apr 16, 2017 at 8:22 PM Dan Yasny <[email protected]> wrote: > >> On Sun, Apr 16, 2017 at 11:19 PM, Konstantin Raskoshnyi < >> [email protected]> wrote: >> >>> Makes sense. >>> I was trying to set it up, but doesn't work with our staging hardware. >>> We have old ilo100, I'll try again. >>> Thanks! >>> >>> >> It is absolutely necessary for any HA to work properly. There's of course >> the "confirm host has been shutdown" option, which serves as an override >> for the fence command, but it's manual >> >> >>> On Sun, Apr 16, 2017 at 8:18 PM Dan Yasny <[email protected]> wrote: >>> >>>> On Sun, Apr 16, 2017 at 11:15 PM, Konstantin Raskoshnyi < >>>> [email protected]> wrote: >>>> >>>>> Fence agent under each node? >>>>> >>>> >>>> When you configure a host, there's the power management tab, where you >>>> need to enter the bmc details for the host. If you don't have fencing >>>> enabled, how do you expect the system to make sure a host running a service >>>> is actually down (and it is safe to start HA services elsewhere), and not, >>>> for example, just unreachable by the engine? How do you avoid a splitbraid >>>> -> SBA ? >>>> >>>> >>>>> >>>>> On Sun, Apr 16, 2017 at 8:14 PM Dan Yasny <[email protected]> wrote: >>>>> >>>>>> On Sun, Apr 16, 2017 at 11:13 PM, Konstantin Raskoshnyi < >>>>>> [email protected]> wrote: >>>>>> >>>>>>> "Corner cases"? >>>>>>> I tried to simulate crash of SPM server and ovirt kept trying to >>>>>>> reistablished connection to the failed node. >>>>>>> >>>>>> >>>>>> Did you configure fencing? >>>>>> >>>>>> >>>>>>> >>>>>>> >>>>>>> On Sun, Apr 16, 2017 at 8:10 PM Dan Yasny <[email protected]> wrote: >>>>>>> >>>>>>>> On Sun, Apr 16, 2017 at 7:29 AM, Nir Soffer <[email protected]> >>>>>>>> wrote: >>>>>>>> >>>>>>>>> On Sun, Apr 16, 2017 at 2:05 PM Dan Yasny <[email protected]> >>>>>>>>> wrote: >>>>>>>>> >>>>>>>>>> >>>>>>>>>> >>>>>>>>>> On Apr 16, 2017 7:01 AM, "Nir Soffer" <[email protected]> wrote: >>>>>>>>>> >>>>>>>>>> On Sun, Apr 16, 2017 at 4:17 AM Dan Yasny <[email protected]> >>>>>>>>>> wrote: >>>>>>>>>> >>>>>>>>>>> When you set up a storage domain, you need to specify a host to >>>>>>>>>>> perform the initial storage operations, but once the SD is defined, >>>>>>>>>>> it's >>>>>>>>>>> details are in the engine database, and all the hosts get connected >>>>>>>>>>> to it >>>>>>>>>>> directly. If the first host you used to define the SD goes down, >>>>>>>>>>> all other >>>>>>>>>>> hosts will still remain connected and work. SPM is an HA service, >>>>>>>>>>> and if >>>>>>>>>>> the current SPM host goes down, SPM gets started on another host in >>>>>>>>>>> the DC. >>>>>>>>>>> In short, unless your actual NFS exporting host goes down, there is >>>>>>>>>>> no >>>>>>>>>>> outage. >>>>>>>>>>> >>>>>>>>>> >>>>>>>>>> There is no storage outage, but if you shutdown the spm host, the >>>>>>>>>> spm host >>>>>>>>>> will not move to a new host until the spm host is online again, >>>>>>>>>> or you confirm >>>>>>>>>> manually that the spm host was rebooted. >>>>>>>>>> >>>>>>>>>> >>>>>>>>>> In a properly configured setup the SBA should take care of that. >>>>>>>>>> That's the whole point of HA services >>>>>>>>>> >>>>>>>>> >>>>>>>>> In some cases like power loss or hardware failure, there is no way >>>>>>>>> to start >>>>>>>>> the spm host, and the system cannot recover automatically. >>>>>>>>> >>>>>>>> >>>>>>>> There are always corner cases, no doubt. But in a normal situation. >>>>>>>> where an SPM host goes down because of a hardware failure, it gets >>>>>>>> fenced, >>>>>>>> other hosts contend for SPM and start it. No surprises there. >>>>>>>> >>>>>>>> >>>>>>>>> >>>>>>>>> Nir >>>>>>>>> >>>>>>>>> >>>>>>>>>> >>>>>>>>>> >>>>>>>>>> Nir >>>>>>>>>> >>>>>>>>>> >>>>>>>>>>> >>>>>>>>>>> On Sat, Apr 15, 2017 at 1:53 PM, Konstantin Raskoshnyi < >>>>>>>>>>> [email protected]> wrote: >>>>>>>>>>> >>>>>>>>>>>> Hi Fernando, >>>>>>>>>>>> I see each host has direct connection nfs mount, but yes, if >>>>>>>>>>>> main host to which I connected nfs storage going down the storage >>>>>>>>>>>> becomes >>>>>>>>>>>> unavailable and all vms are down >>>>>>>>>>>> >>>>>>>>>>>> >>>>>>>>>>>> On Sat, Apr 15, 2017 at 10:37 AM FERNANDO FREDIANI < >>>>>>>>>>>> [email protected]> wrote: >>>>>>>>>>>> >>>>>>>>>>>>> Hello Konstantin. >>>>>>>>>>>>> >>>>>>>>>>>>> That doesn`t make much sense make a whole cluster depend on a >>>>>>>>>>>>> single host. From what I know any host talk directly to NFS >>>>>>>>>>>>> Storage Array >>>>>>>>>>>>> or whatever other Shared Storage you have. >>>>>>>>>>>>> Have you tested that host going down if that affects the other >>>>>>>>>>>>> with the NFS mounted directlly in a NFS Storage array ? >>>>>>>>>>>>> >>>>>>>>>>>>> Fernando >>>>>>>>>>>>> >>>>>>>>>>>>> 2017-04-15 12:42 GMT-03:00 Konstantin Raskoshnyi < >>>>>>>>>>>>> [email protected]>: >>>>>>>>>>>>> >>>>>>>>>>>>>> In ovirt you have to attach storage through specific host. >>>>>>>>>>>>>> If host goes down storage is not available. >>>>>>>>>>>>>> >>>>>>>>>>>>>> On Sat, Apr 15, 2017 at 7:31 AM FERNANDO FREDIANI < >>>>>>>>>>>>>> [email protected]> wrote: >>>>>>>>>>>>>> >>>>>>>>>>>>>>> Well, make it not go through host1 and dedicate a storage >>>>>>>>>>>>>>> server for running NFS and make both hosts connect to it. >>>>>>>>>>>>>>> In my view NFS is much easier to manage than any other type >>>>>>>>>>>>>>> of storage, specially FC and iSCSI and performance is pretty >>>>>>>>>>>>>>> much the same, >>>>>>>>>>>>>>> so you won`t get better results other than management going to >>>>>>>>>>>>>>> other type. >>>>>>>>>>>>>>> >>>>>>>>>>>>>>> Fernando >>>>>>>>>>>>>>> >>>>>>>>>>>>>>> 2017-04-15 5:25 GMT-03:00 Konstantin Raskoshnyi < >>>>>>>>>>>>>>> [email protected]>: >>>>>>>>>>>>>>> >>>>>>>>>>>>>>>> Hi guys, >>>>>>>>>>>>>>>> I have one nfs storage, >>>>>>>>>>>>>>>> it's connected through host1. >>>>>>>>>>>>>>>> host2 also has access to it, I can easily migrate >>>>>>>>>>>>>>>> vms between them. >>>>>>>>>>>>>>>> >>>>>>>>>>>>>>>> The question is - if host1 is down - all infrastructure is >>>>>>>>>>>>>>>> down, since all traffic goes through host1, >>>>>>>>>>>>>>>> is there any way in oVirt to use redundant storage? >>>>>>>>>>>>>>>> >>>>>>>>>>>>>>>> Only glusterfs? >>>>>>>>>>>>>>>> >>>>>>>>>>>>>>>> Thanks >>>>>>>>>>>>>>>> >>>>>>>>>>>>>>>> >>>>>>>>>>>>>>>> _______________________________________________ >>>>>>>>>>>>>>>> Users mailing list >>>>>>>>>>>>>>>> [email protected] >>>>>>>>>>>>>>>> http://lists.ovirt.org/mailman/listinfo/users >>>>>>>>>>>>>>>> >>>>>>>>>>>>>>>> >>>>>>>>>>>>> >>>>>>>>>>>> _______________________________________________ >>>>>>>>>>>> Users mailing list >>>>>>>>>>>> [email protected] >>>>>>>>>>>> http://lists.ovirt.org/mailman/listinfo/users >>>>>>>>>>>> >>>>>>>>>>>> >>>>>>>>>>> _______________________________________________ >>>>>>>>>>> Users mailing list >>>>>>>>>>> [email protected] >>>>>>>>>>> http://lists.ovirt.org/mailman/listinfo/users >>>>>>>>>>> >>>>>>>>>> >>>>>>>>>> _______________________________________________ >>>>>>>>>> Users mailing list >>>>>>>>>> [email protected] >>>>>>>>>> http://lists.ovirt.org/mailman/listinfo/users >>>>>>>>>> >>>>>>>>>> >>>>>>>>>>
_______________________________________________ Users mailing list [email protected] http://lists.ovirt.org/mailman/listinfo/users