And also, do I need an account to login to jira to create the issue?
Dr. ir. H.M. (Michel) Bohms Sr. Research Scientist Structural Reliability T +31 (0)88 866 31 07 M +31 (0)63 038 12 20 E michel.bo...@tno.nl<mailto:michel.bo...@tno.nl> Location<http://www.tno.nl/locaties/DTM> [cid:image001.gif@01D13838.03B56A80]<http://www.tno.nl/> This message may contain information that is not intended for you. If you are not the addressee or if this message was sent to you by mistake, you are requested to inform the sender and delete the message. TNO accepts no liability for the content of this e-mail, for the manner in which you use it and for damage of any kind resulting from the risks inherent to the electronic transmission of messages. From: Michel Böhms [mailto:michel.bo...@gmail.com] Sent: woensdag 16 december 2015 19:21 To: users@marmotta.apache.org Subject: Re: sparql issue ok, I'll do that in the meantime, where can I increase the default (linux version)? (although unlikely it is a time issue, removing the # doesnt change the situation that much :) thx a lot Michel 2015-12-16 16:33 GMT+01:00 Sergio Fernández <wik...@apache.org<mailto:wik...@apache.org>>: Hi Michael, I doesn't give no results, the query execution gets aborted because it exceeds the timeout (by default 60s). I guess it could be an issue handling xsd:dateTime literals. Please, report the details to jira, with a sample dataset if possible, and we'll try to find the issue. Cheers, On Wed, Dec 16, 2015 at 3:47 PM, Bohms, H.M. (Michel) <michel.bo...@tno.nl<mailto:michel.bo...@tno.nl>> wrote: Strange issue: PREFIX rdf: <http://www.w3.org/1999/02/22-rdf-syntax-ns#<http://www.w3.org/1999/02/22-rdf-syntax-ns>> PREFIX xsd: <http://www.w3.org/2001/XMLSchema#<http://www.w3.org/2001/XMLSchema>> PREFIX odysseus: <http://marmotta.tno.nl:8080/marmotta/context/> PREFIX cmo: <http://www.modelservers.org/public/ontologies/cmo/cmo.ttl#<http://www.modelservers.org/public/ontologies/cmo/cmo.ttl>> PREFIX depc: <http://www.modelservers.org/public/ontologies/odysseus/depc.ttl#<http://www.modelservers.org/public/ontologies/odysseus/depc.ttl>> SELECT ?ProfileSignal ?signalid ?value ?valueType ?timestamp FROM odysseus:manchestertest WHERE { { ?ProfileSignal a depc:ProfileSignal . ?ProfileSignal depc:signalID ?signalid . ?ProfileSignal depc:hasTimePointSignal ?tps . ?tps cmo:energy ?value . # ?tps depc:timeStamp ?timestamp . { FILTER (?signalid = "1771"^^xsd:int). } bind ("depc:eFlow" as ?valueType) } } Gives results, but uncommenting # gives no results! Reproducible at: http://marmotta.tno.nl:8080/marmotta/sparql/admin/squebi.html#?query=PREFIX%20rdf:%20%3Chttp:%2F%2Fwww.w3.org%2F1999%2F02%2F22-rdf-syntax-ns%23%3E%20%0APREFIX%20xsd:%20%3Chttp:%2F%2Fwww.w3.org%2F2001%2FXMLSchema%23%3E%20%0APREFIX%20odysseus:%20%3Chttp:%2F%2Fmarmotta.tno.nl:8080%2Fmarmotta%2Fcontext%2F%3E%20%0APREFIX%20cmo:%20%3Chttp:%2F%2Fwww.modelservers.org%2Fpublic%2Fontologies%2Fcmo%2Fcmo.ttl%23%3E%20%0APREFIX%20depc:%20%3Chttp:%2F%2Fwww.modelservers.org%2Fpublic%2Fontologies%2Fodysseus%2Fdepc.ttl%23%3E%20%0ASELECT%20%3FProfileSignal%20%3Fsignalid%20%3Fvalue%20%3FvalueType%20%3Ftimestamp%20%0AFROM%20odysseus:manchestertest%20%0A%20WHERE%20%0A%20%20%7B%20%0A%20%20%20%20%3FProfileSignal%20a%20depc:ProfileSignal%20.%20%0A%20%20%20%20%3FProfileSignal%20depc:signalID%20%3Fsignalid%20.%20%0A%20%20%20%20%3FProfileSignal%20depc:hasTimePointSignal%20%3Ftps%20.%20%0A%20%20%20%20%3Ftps%20cmo:energy%20%3Fvalue%20.%20%0A%20%23%20%20%20%3Ftps%20depc:timeStamp%20%3Ftimestamp%20.%20%0A%20%20%20%20%7B%20%0A%20%20%20%20%20%20FILTER%20(%3Fsignalid%20%3D%20%221771%22%5E%5Exsd:int).%20%0A%20%20%20%20%7D%20%0A%20%20%20%20bind%20(%22depc:eFlow%22%20as%20%3FvalueType)%20%0A%20%20%7D%20%0A%0A&writer=browse Any idea/hint welcome! Thx a lot, Michel Bohms/Erwin Somers, TNO Dr. ir. H.M. (Michel) Bohms Sr. Research Scientist Structural Reliability T +31 (0)88 866 31 07 M +31 (0)63 038 12 20 E michel.bo...@tno.nl<mailto:michel.bo...@tno.nl> Location<http://www.tno.nl/locaties/DTM> [cid:image001.gif@01D13838.03B56A80]<http://www.tno.nl/> This message may contain information that is not intended for you. If you are not the addressee or if this message was sent to you by mistake, you are requested to inform the sender and delete the message. TNO accepts no liability for the content of this e-mail, for the manner in which you use it and for damage of any kind resulting from the risks inherent to the electronic transmission of messages. -- Sergio Fernández Partner Technology Manager Redlink GmbH m: +43 6602747925<tel:%2B43%206602747925> e: sergio.fernan...@redlink.co<mailto:sergio.fernan...@redlink.co> w: http://redlink.co<http://redlink.co/>