Hi folks,

I'm trying to setup first an SCF calculation and eventually a band structure 
and relaxation calculation of a system with a NaCl-like lattice. Right now I 
have an input file with 64 atoms in a cube shape, which corresponds to 8 unit 
cells of the NaCl crystal structure. I've specified the CELL_PARAMETERS as well 
as the atomic coordinates and chosen ibrav = 0. I'm getting the following 
warning:

Message from routine setup:
     using ibrav=0 with symmetry is DISCOURAGED, use correct ibrav instead


  1.  What is the correct solution for setting up my supercell; should I be 
using ibrav = 1 instead and specifying the vectors for repeating my super cell?
  2.  For my own understanding, what is the issue with using symmetry with 
ibrav=0? By symmetry am I correct to assume that this warning is referring to 
symmetry detection within the supercell? If so, how does specifying ibrav=1 
help with symmetry detection?
  3.  For what it's worth, it looks like symmetry detection is occurring at 
some level since the code output "Found identity + (  0.0000  0.2500  0.2500) 
symmetry". However, I would expect to also see (0.25, 0, 0.25) and (0.25, 0, 
0.25) as symmetry operations for an NaCl structure so perhaps there is a 
problem here after all. Am I understanding correctly?

Best regards,
Ian Dunn (he/him)
ASML Wilton MDEV Analysis Architect

--- The information contained in this communication and any attachments is 
confidential and may be privileged, and is for the sole use of the intended 
recipient(s). Any unauthorized review, use, disclosure or distribution is 
prohibited. Unless explicitly stated otherwise in the body of this 
communication or the attachment thereto (if any), the information is provided 
on an AS-IS basis without any express or implied warranties or liabilities. To 
the extent you are relying on this information, you are doing so at your own 
risk. If you are not the intended recipient, please notify the sender 
immediately by replying to this message and destroy all copies of this message 
and any attachments. Neither the sender nor the company/group of companies he 
or she represents shall be liable for the proper and complete transmission of 
the information contained in this communication, or for any delay in its 
receipt.
_______________________________________________________________________________
The Quantum ESPRESSO Foundation stands in solidarity with all civilians 
worldwide who are victims of terrorism, military aggression, and indiscriminate 
warfare.
--------------------------------------------------------------------------------
Quantum ESPRESSO is supported by MaX (www.max-centre.eu)
users mailing list users@lists.quantum-espresso.org
https://lists.quantum-espresso.org/mailman/listinfo/users

Reply via email to