On Fri, Jun 21, 2013 at 5:21 PM, Steven Stern
<subscribed-li...@sterndata.com> wrote:
>> Today, I am getting this message at boot time:
>>
>> "Notice - HD self monitoring system has reported that a parameter has
>> exceeded its normal operating range.  Dell recommends that you back up
>> your data regularly.  A parameter out of range may or may not indicate
>> a potential Hard.    Press F1 to continue , F2 to enter setup"
>>
>> Is there any reason to be worried about?
>>
>> My computer is about 3 years old.
>
> For each drive on your system, try
>
>    sudo smartctl -H /dev/sdx
>
> where x=a,b,c,.... etc
>
> If any indicate poor health, then use "--all" in place of -H
>
> However, yeah, it's probably time to get a really good backup and price
> a replacement drive.


Thanks, Steve. I am getting the following:

# smartctl -H /dev/sda
smartctl 6.1 2013-03-16 r3800 [x86_64-linux-3.9.6-200.fc18.x86_64] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: FAILED!
Drive failure expected in less than 24 hours. SAVE ALL DATA.
Failed Attributes:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE
UPDATED  WHEN_FAILED RAW_VALUE
  5 Reallocated_Sector_Ct   0x0033   013   013   036    Pre-fail
Always   FAILING_NOW 3587

#

Paul
-- 