Hi, If you have S@TML you’ll need a gateway to transform the S@TML into compliant ByteCode (check the SIMAlliance S@T specifications, v4.0) that can be interpreted by the applet. The SMPP is just for message submission. In any case, the UDH will be 02 70 00 for a single message or 07 00 05 XX YY ZZ 70 00 where XX is the same ID for all concatenated messages in the group, YY is the number of messages in total and ZZ is maintaining order.
Cheers, Christopher Burke http://simulity.com Office: +44 (0) 1248 679 281 Fax: +44 (0) 1248 660 323 Skype:krslynx UK Unit 8, Ash Court, Parc Menai, Bangor, Gwynedd, LL57 4DF, Wales, UK Malaysia Level 30, The Gardens North Tower, Mid Valley City, Lingkaran Syed Putra, 59200, Kuala Lumpur, Malaysia NOTICE: This message contains privileged & confidential information intended only for the use of the addressee named above. If you are not the intended recipient of this message, you are hereby notified that you must not disseminate, copy or take any action in reliance on it. If you have received this message in error, please notify Simulity Labs immediately. Any views expressed in this message are those of the individual sender except where the sender specifically states them to be the view of Simulity Labs On 20 November 2014 at 22:07:16, Osman (olgsevi...@gmail.com) wrote: Hello everyone, How shoud I form the UDH for sending a message to the SIM Toolkit? To send S@tml over smpp.