Hi Kannel Users,
I am having some issues with Kannel... I have multiple SMSC binds from a vendor to kannel grouped as same name using 'smsc-id' configuration directive. Each bind transmit the message from different shortcode... when my application sends back the message to Kannel, it is routed to any bind where as I want to direct it specific bind which is bind to use that shortcode.
Here is my configs #For shortcode 6261 group = smsc smsc = smpp smsc-id = Network_O host = a.b.c.d port = 1234 alt-charset = ROMAN8 alt-addr-charset = GSM transceiver-mode = yes smsc-username = "user" smsc-password = password system-type = "VMA" allowed-smsc-id = Network_O #For shortcode 6262 group = smsc smsc = smpp smsc-id = Network_O host = e.f.g.h port = 1235 alt-charset = ROMAN8 alt-addr-charset = GSM transceiver-mode = yes smsc-username = "user" smsc-password = password system-type = "VMA" allowed-smsc-id = Network_O Any help is this regard would be great. Regards, Ishtiaq Ahmed