Hi, Am 06.03.2016 um 17:56 schrieb Yuri Burmachenko:
> Hallo to distinguished forum members, > > Is there any limit of grid nodes in SoGE 8.1.8. > > We see in the qmaster spool message the following notice: > qmaster will accept max. 950 dynamic event clients There is a setting of MAX_DYN_EC in SGE's configuration `qconf -mconf` , but should default to 99. Did you increase it already beyond it to 950? -- Reuti > Does this mean that the limit is 950 grid nodes? > Is it possible to increase this number? > > What are our options if we reach 950 grid nodes – how can we scale further? > > Any tips and advices, will be greatly appreciated. > Thank You. > > > > Yuri Burmachenko | Sr. Engineer | IT | Mellanox Technologies Ltd. > Work: +972 74 7236386 | Cell +972 54 7542188 |Fax: +972 4 959 3245 > Follow us on Twitter and Facebook > > _______________________________________________ > users mailing list > users@gridengine.org > https://gridengine.org/mailman/listinfo/users _______________________________________________ users mailing list users@gridengine.org https://gridengine.org/mailman/listinfo/users