Hi, Can you share the full logs ?
-Wei On Wed, 15 Mar 2023 at 12:41, Jafar Aghabalayev < [email protected]> wrote: > Try to reboot management server, after several time unsuccessful attempt > to run system vms for now it event don’t try to start them. Screenshot > attached. > > > > Regards, > > Jafar Aghabalayev > > *From:* Jafar Aghabalayev <[email protected]> > *Sent:* Wednesday, March 15, 2023 10:54 AM > *To:* [email protected] > *Subject:* SystemVMs not starting after host reboot > > > > *CAUTION:* This email originated from outside the organization. Do not > click links or open attachments unless you recognize the sender and know > the content is safe. Please report all suspicious emails to > [email protected]. > > Hello community, > > Recently I rebooted the KVM host where systems running. After rebooting > the KVM hosts System VMs unable to start. > > I can successfully create guest VMs. > > > > Cloudstack version: 4.17.2.0 > > > > The log from management server: > > > > 2023-03-15 02:42:09,545 WARN [c.c.c.ConsoleProxyManagerImpl] > (consoleproxy-1:ctx-ddaed1ac) (logid:ef20fea1) Unable to start proxy [1002] > due to [Unable to create a deployment for VM instance {id: "1002", name: > "v-1002-VM", uuid: "dccce3c6-7e8b-4449-8968-84b99143eac7", > type="ConsoleProxy"}]. > > com.cloud.exception.InsufficientServerCapacityException: Unable to create > a deployment for VM instance {id: "1002", name: "v-1002-VM", uuid: > "dccce3c6-7e8b-4449-8968-84b99143eac7", type="ConsoleProxy"}Scope=interface > com.cloud.dc.DataCenter; id=1 > > 2023-03-15 02:42:09,548 INFO [c.c.c.ConsoleProxyManagerImpl] > (consoleproxy-1:ctx-ddaed1ac) (logid:ef20fea1) Unable to start console > proxy vm for standby capacity, vm id : 1002, will recycle it and start a > new one > > 2023-03-15 02:42:09,558 WARN [o.a.c.s.SecondaryStorageManagerImpl] > (secstorage-1:ctx-47af890a) (logid:e6c491cc) Unable to start secondary > storage VM [1003] due to [Unable to create a deployment for VM instance > {id: "1003", name: "s-1003-VM", uuid: > "fc61476a-50e7-426f-8cd6-82ef1dbbe144", type="SecondaryStorageVm"}]. > > com.cloud.exception.InsufficientServerCapacityException: Unable to create > a deployment for VM instance {id: "1003", name: "s-1003-VM", uuid: > "fc61476a-50e7-426f-8cd6-82ef1dbbe144", > type="SecondaryStorageVm"}Scope=interface com.cloud.dc.DataCenter; id=1 > > 2023-03-15 02:42:09,561 INFO [o.a.c.s.SecondaryStorageManagerImpl] > (secstorage-1:ctx-47af890a) (logid:e6c491cc) Unable to start secondary > storage VM [1003] for standby capacity, it will be recycled and will start > a new one. > > 2023-03-15 02:42:10,464 DEBUG [o.a.c.u.p.ProcessRunner] > (pool-2-thread-32:null) (logid:e5e27136) Process standard error output > command [/usr/bin/ipmitool -I lanplus -R 1 -v -H 10.220.65.12 -p 623 -U > Administrator -P ******* chassis power status]: [Unable to Get Channel > Cipher Suites > > Error response 0xc1 from Get PICMG Properities > > Invalid completion code received: Invalid command > > 2023-03-15 02:42:10,501 DEBUG [o.a.c.u.p.ProcessRunner] > (pool-2-thread-31:null) (logid:e5e27136) Process standard error output > command [/usr/bin/ipmitool -I lanplus -R 1 -v -H 10.220.65.11 -p 623 -U > Administrator -P ******* chassis power status]: [Unable to Get Channel > Cipher Suites > > Error response 0xc1 from Get PICMG Properities > > Invalid completion code received: Invalid command > > 2023-03-15 02:42:11,572 DEBUG [c.c.a.ConsoleProxyAlertAdapter] > (consoleproxy-1:ctx-ddaed1ac) (logid:ef20fea1) Console proxy creation > failure, zone: Zone-1 > > 2023-03-15 02:42:11,573 WARN [c.c.a.AlertManagerImpl] > (consoleproxy-1:ctx-ddaed1ac) (logid:ef20fea1) alertType=[10] > dataCenterId=[1] podId=[null] clusterId=[null] message=[Console proxy > creation failure. zone: Zone-1, error details: null]. > > 2023-03-15 02:42:11,576 WARN [c.c.a.AlertManagerImpl] > (consoleproxy-1:ctx-ddaed1ac) (logid:ef20fea1) No recipients set in global > setting 'alert.email.addresses', skipping sending alert with subject > [Console proxy creation failure. zone: Zone-1, error details: null] and > content [Console proxy creation failure (zone Zone-1)]. > > 2023-03-15 02:42:11,577 DEBUG [c.c.a.SecondaryStorageVmAlertAdapter] > (secstorage-1:ctx-47af890a) (logid:e6c491cc) Secondary Storage Vm creation > failure, zone: Zone-1 > > 2023-03-15 02:42:11,578 WARN [c.c.a.AlertManagerImpl] > (secstorage-1:ctx-47af890a) (logid:e6c491cc) alertType=[19] > dataCenterId=[1] podId=[null] clusterId=[null] message=[Secondary Storage > Vm creation failure. zone: Zone-1, error details: null]. > > 2023-03-15 02:42:11,581 WARN [c.c.a.AlertManagerImpl] > (secstorage-1:ctx-47af890a) (logid:e6c491cc) No recipients set in global > setting 'alert.email.addresses', skipping sending alert with subject > [Secondary Storage Vm creation failure. zone: Zone-1, error details: null] > and content [Secondary Storage Vm creation failure (zone Zone-1)]. > > > > Appreciate your support. > > > > > > Regards, > > > > > > *Jafar Aghabalayev | Senior IT Infrastructure Engineer* > > 157 Azadliq Avenue, AZ1106, Baku, Azerbaijan > > mob: +994 55 900 19 34 > > email: [email protected] > > > > This communication contains information issued by "PASHA Technology" LLC. > This e-mail message and all attachments transmitted with it are intended > solely for the use of the addressee and may contain legally privileged and > confidential information. If the reader of this message is not the intended > recipient, or an employee or agent responsible for delivering this message > to the intended recipient, the reader is hereby notified that any > dissemination, distribution, copying, or other use of this message or its > attachments is strictly prohibited. If you have received this message in > error, please notify the sender immediately by replying to this message and > please delete it from your computer. Within the bounds of law "PASHA > Technology" LLC may monitor electronic transmissions through its internal > and external networks to ensure compliance with internal policies and for > legitimate business purposes. > > >