> So migrating my primary storage to iSCSI would (as a side effect) disable the 
> fencing/rebooting?

I can't be 100% sure about that but that's what I got from running through the 
code. I don't have a setup ATM where I could test this to confirm.

Regards,
Somesh


-----Original Message-----
From: Frank Louwers [mailto:[email protected]] 
Sent: Wednesday, August 19, 2015 3:55 PM
To: [email protected]
Subject: RE: CS Manager down: all hypervisors reboot

So migrating my primary storage to iSCSI would (as a side effect) disable the 
fencing/rebooting? 


On 19 Aug 2015 at 21:46:35, Somesh Naidu ([email protected]) wrote:

> how would this work if primary storage were eg iSCSI? 
I believe we perform the heartbeat check and host fencing for NFS storage only. 

> Is there no way to disable that, except for modifying kvmheartbeat.sh? 
AFAIK, there isn't. 

Reply via email to