Filed ticket https://issues.apache.org/jira/browse/FLINK-31949 to track
this issue.

On Thu, Apr 27, 2023 at 11:14 AM Dian Fu <dian0511...@gmail.com> wrote:

> Hi Urs,
>
> I guess you are right. This seems like a bug which should be addressed.
>
> Regards,
> Dian
>
> On Mon, Apr 24, 2023 at 5:07 AM Urs Schönenberger <
> urs.schoenenber...@tngtech.com> wrote:
>
>> Hi all,
>>
>> In FLINK-26444, a couple of convenience window assigners were added to
>> the Python Datastream API, including CountTumblingWindowAssigner. This
>> assigner uses a CountTrigger by default, which produces
>> TriggerResult.FIRE.
>>
>> As such, using this window assigner on a data stream will always produce
>> a "state leak" since older count windows will always be retained without
>> any chance to work on the elements again.
>>
>> Unless I am mistaken, the only way to use this assigner would be to
>> override its trigger with .trigger() afterwards? In this case, should
>> the default trigger for this assigner not be one with a
>> TriggerResult.FIRE_AND_PURGE?
>>
>> Would be happy to file a bug and/or produce a PR for this but wanted to
>> check with the list first to make sure I'm not missing anything here.
>>
>> Thanks,
>> Urs
>>
>> --
>> Urs Schönenberger * urs.schoenenber...@tngtech.com
>> TNG Technology Consulting GmbH, Beta-Str. 13a, 85774 Unterföhring
>> Geschäftsführer: Henrik Klagges, Dr. Robert Dahlke, Thomas Endres
>> Aufsichtsratsvorsitzender: Christoph Stock
>> Sitz: Unterföhring * Amtsgericht München * HRB 135082
>>
>

Reply via email to