This is a known and documented
<https://nightlies.apache.org/flink/flink-docs-release-1.14/docs/deployment/elastic_scaling/#limitations-1>
limitation of the AdaptiveScheduler. There is no concrete date yet for
when it will be fixed.
On 12/10/2021 05:08, ChangZhuo Chen (陳昌倬) wrote:
Hi,
We found that parallelism in web UI are inconsistent when using reactive
mode. As in attachment, in overview page, all parallelism values are 1,
which is not correct one. When clicking operator for detail information,
the parallelism in detail information is the correct one.
Is it possible to fix this inconsistent so that it would not confused
engineer when deploying Flink application.