Hi all,
The way I understand the matter is that the described behavior is intentional
for event time timers:
* When called, an event time handler can register new timers
· The timestamp parameter (override def onTimer(timestamp: Long, ctx:
KeyedProcessFunction[K, I, O]#OnTimerContext, out: Collector[O]): Unit = { …)
* Is set to the timeout time of the timer, not the watermark that caused
the timeout !
* onTimer, as said, can register new timers, timeout time can even be in
the past,
* in that case the timeout is handled immediately after current onTimer(…)
call
* as long as onTimer registers new timers it will iterate through all these
timers
When an operator receives a watermark it fires all registered timers with
timeout <= watermark, in timeout order, also the ones registered in onTimer().
This is especially the case for a MAX_WATERMARK watermark, but will be the
same for any watermark that lies in the future.
For your case, @Marco, you could break this pattern by comparing the timeout to
be registered with current processing time and if that lies safely too much in
the future: not register the timeout.
That would break the infinite iteration over timers …
I believe the behavior exhibited by flink is intentional and no defect!
What do you think?
Thias
From: JING ZHANG <[email protected]>
Sent: Freitag, 24. September 2021 12:25
To: Guowei Ma <[email protected]>
Cc: Marco Villalobos <[email protected]>; user <[email protected]>
Subject: Re: stream processing savepoints and watermarks question
Hi Guowei,
Thanks for quick response, maybe I didn't express it clearly in the last email.
In fact, above case happened in reality, not what I imagined.
When MAX_WATERMARK is received, the operator will try to fire all registered
event-time timers. However in the above case, new timers are continuous being
registered.
I would try to reproduce the problem in an ITCase, and once completed I would
provide the code.
Best,
JING ZHANG
Guowei Ma <[email protected]<mailto:[email protected]>> 于2021年9月24日周五
下午5:16写道:
Hi, JING
Thanks for the case.
But I am not sure this would happen. As far as I know the event timer could
only be triggered when there is a watermark (except the "quiesce phase").
I think it could not advance any watermarks after MAX_WATERMARK is received.
Best,
Guowei
On Fri, Sep 24, 2021 at 4:31 PM JING ZHANG
<[email protected]<mailto:[email protected]>> wrote:
Hi Guowei,
I could provide a case that I have encountered which timers to fire
indefinitely when doing drain savepoint.
After an event timer is triggered, it registers another event timer whose value
equals the value of triggered timer plus an interval time.
If a MAX_WATERMARK comes, the timer is triggered, then registers another timer
and forever.
I'm not sure whether Macro meets a similar problem.
Best,
JING ZHANG
Guowei Ma <[email protected]<mailto:[email protected]>> 于2021年9月24日周五
下午4:01写道:
Hi Macro
Indeed, as mentioned by JING, if you want to drain when triggering savepoint,
you will encounter this MAX_WATERMARK.
But I have a problem. In theory, even with MAX_WATERMARK, there will not be an
infinite number of timers. And these timers should be generated by the
application code.
You can share your code if it is convenient for you.
Best,
Guowei
On Fri, Sep 24, 2021 at 2:02 PM JING ZHANG
<[email protected]<mailto:[email protected]>> wrote:
Hi Macro,
Do you specified drain flag when stop a job with a savepoint?
If the --drain flag is specified, then a MAX_WATERMARK will be emitted before
the last checkpoint barrier.
[1]
https://ci.apache.org/projects/flink/flink-docs-master/docs/deployment/cli/#stopping-a-job-gracefully-creating-a-final-savepoint
Best,
JING ZHANG
Marco Villalobos <[email protected]<mailto:[email protected]>>
于2021年9月24日周五 下午12:54写道:
Something strange happened today.
When we tried to shutdown a job with a savepoint, the watermarks became equal
to 2^63 - 1.
This caused timers to fire indefinitely and crash downstream systems with
overloaded untrue data.
We are using event time processing with Kafka as our source.
It seems impossible for a watermark to be that large.
I know its possible stream with a batch execution mode. But this was stream
processing.
What can cause this? Is this normal behavior when creating a savepoint?
Diese Nachricht ist ausschliesslich für den Adressaten bestimmt und beinhaltet
unter Umständen vertrauliche Mitteilungen. Da die Vertraulichkeit von
e-Mail-Nachrichten nicht gewährleistet werden kann, übernehmen wir keine
Haftung für die Gewährung der Vertraulichkeit und Unversehrtheit dieser
Mitteilung. Bei irrtümlicher Zustellung bitten wir Sie um Benachrichtigung per
e-Mail und um Löschung dieser Nachricht sowie eventueller Anhänge. Jegliche
unberechtigte Verwendung oder Verbreitung dieser Informationen ist streng
verboten.
This message is intended only for the named recipient and may contain
confidential or privileged information. As the confidentiality of email
communication cannot be guaranteed, we do not accept any responsibility for the
confidentiality and the intactness of this message. If you have received it in
error, please advise the sender by return e-mail and delete this message and
any attachments. Any unauthorised use or dissemination of this information is
strictly prohibited.