I have an update. I have created a small project on github, https://github.com/daha/flink-key-by-problem-with-rocksdb-state, which reproduces the issue.
There seems to be problem with RocksDB in all versions I have tested (from 1.7.1 and later). In Flink 1.9.x only one of the events is counted with RockDB. In Flink 1.10.x and later all events are counted but with separate keys when all/both events should be counted using the same key. The main branch in my sample project is using Flink 1.11.3, then there are branches for Flink 1.9.1, 1.10.3 and 1.12.1. Best regards, /David Haglund From: David Haglund <david.hagl...@niradynamics.se> Date: Wednesday, 20 January 2021 at 09:38 I have encountered a problem in Flink when trying to upgrade from Flink 1.9.1 to Flink 1.11.3. The problem in a combination of 2 components: * Keys implemented as case classes in Scala where we override the equals and hashCode methods. The case class has additional fields which we are not used in the keyBy (hashCode/equals) but can have different values for a specific key (the fields we care about). * Checkpointing with RocksDB In Flink 1.9.1 everything worked fine, but in Flink 1.11.3 we got aggregations for each unique key including the parameters which we did not want to include in the keyBy, which we exclicitly do not use in hashCode and equals. It looks likes hashCode is ignored in the keyBy in our case when we use RocksDB for checkpoints. We do not see this problem if we disable checkpointing or when using FsStateBackend. I have seen this with "Incremental Window Aggregation with AggregateFunction" [1], but a colleague of mine reported he had seen the same issue with KeyedProcessFunction too. We are using Scala version 2.11.12 and Java 8. This looks like a bug to me. Is it a known issue or a new one? Best regards, /David Haglund [1] Incremental Window Aggregation with AggregateFunction https://ci.apache.org/projects/flink/flink-docs-release-1.11/dev/stream/operators/windows.html#incremental-window-aggregation-with-aggregatefunction David Haglund Systems Engineer Fleet Perception for Maintenance [cid:image001.png@01D6EF66.68FF41F0] NIRA Dynamics AB Wallenbergs gata 4 58330 Linköping Sweden Mobile: +46 705 634 848 david.hagl...@niradynamics.se www.niradynamics.se Together for smarter safety