Thank you for the reply and look forward to the advice of Till. Anyang
Peter Huang <huangzhenqiu0...@gmail.com> 于2019年9月5日周四 下午11:53写道: > Hi Anyang, > > Thanks for raising it up. I think it is reasonable as what you requested > is needed for batch. Let's wait for Till to give some more input. > > > > Best Regards > Peter Huang > > On Thu, Sep 5, 2019 at 7:02 AM Anyang Hu <huanyang1...@gmail.com> wrote: > >> Hi Peter&Till: >> >> As commented in the issue >> <https://issues.apache.org/jira/browse/FLINK-10868#>,We have introduced >> the FLINK-10868 <https://issues.apache.org/jira/browse/FLINK-10868> patch >> (mainly batch tasks) online, what do you think of the following two >> suggestions: >> >> 1) Parameter control time interval. At present, the default time >> interval of 1 min is used, which is too short for batch tasks; >> >> 2)Parameter Control When the failed Container number reaches >> MAXIMUM_WORKERS_FAILURE_RATE and JM disconnects whether to perform >> OnFatalError so that the batch tasks can exit as soon as possible. >> >> Best regards, >> Anyang >> >