Hi Vipul,
  Thanks for the information.  Yes, I do have checkpointing enabled with 10
millisecs.
  I think the issue here is that the stream ended before the checkpoint
reached.  This is a testing code that the DataStream only have 5 events then
it ended. Once the stream ended, the checkpoint is not triggered, then the
file remains in "pending" state.
  Anyway we can force a checkpoint trigger? or let the sink know the stream
ended? 
Thanks,
Tao



--