Hi, in addition to the video I would also like to point out that the Continuous triggers should only be used with the GlobalWindows assigner. For TimeWindows the right thing to do would be using the EventTimeTrigger (or ProcessingTimeTrigger in case you are doing processing time windows).
Could you maybe go into some detail of what you are trying to achieve? Then we can figure out what a good strategy would be. Cheers, Aljoscha > On 25 Feb 2016, at 04:27, Gavin Lin <avido...@gmail.com> wrote: > > Hi, > > how about this video ? > https://www.youtube.com/watch?v=T7hiwcwCXGI > > Gavin.Lin > > 2016-02-25 3:55 GMT+08:00 Ankur Sharma <an...@stud.uni-saarland.de>: > Hey, > > Can you guide me to some example of ContinuousProcessingTimeTrigger? > I want to partition input stream into TimeWindow that should fire at > continuous time interval on its on without waiting for a new element to enter > the stream. > Could you guide me to it? > > > Thanks > > Best, > Ankur Sharma > Information Systems Group > 3.15 E1.1 Universität des Saarlandes > 66123, Saarbrücken Germany > Email: ankur.sha...@mpi-inf.mpg.de > an...@stud.uni-saarland.de >