Hi,

Had the same problem this morning, seems related to the leap second bug.
Rebooting the nodes fixed it for me, but there seems to be a fix also without 
rebooting the server.

Kind regards,
Pieter

From: feedly team [mailto:feedly...@gmail.com]
Sent: maandag 2 juli 2012 17:09
To: user@cassandra.apache.org
Subject: frequent node up/downs

Hello,
   I recently set up a 2 node cassandra cluster on dedicated hardware. In the 
logs there have been a lot of "InetAddress xxx is now dead' or UP messages. 
Comparing the log messages between the 2 nodes, they seem to coincide with 
extremely long ParNew collections. I have seem some of up to 50 seconds. The 
installation is pretty vanilla, I didn't change any settings and the machines 
don't seem particularly busy - cassandra is the only thing running on the 
machine with an 8GB heap. The machine has 64GB of RAM and CPU/IO usage looks 
pretty light. I do see a lot of 'Heap is xxx full. You may need to reduce 
memtable and/or cache sizes' messages. Would this help with the long ParNew 
collections? That message seems to be triggered on a full collection.

Reply via email to