> smart - технология винта, а не шины.
> с чего он должен зависеть от способа подключеня ?)
кажись, все работает. правда, автоопределение он ниасилил, пришлось вручную
игшраться с опцией -d. вывод в аттаче
srv> ~$ sudo smartctl -d sat -a /dev/sdb
smartctl 5.41 2011-06-09 r3365 [i686-linux-2.6.34.7-292] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Device Model: SAMSUNG HM502JX
Serial Number: 33011F14AAE2UM
LU WWN Device Id: 5 0000f0 0aafb00e2
Firmware Version: 2AC101C4
User Capacity: 500Â 107Â 862Â 016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 8
ATA Standard is: ATA-8-ACS revision 6
Local Time is: Wed Jul 27 10:36:20 2011 MSD
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 8160) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off
support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 136) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED
WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 100 100 051 Pre-fail Always
- 1403
2 Throughput_Performance 0x0026 252 252 000 Old_age Always
- 0
3 Spin_Up_Time 0x0023 090 087 025 Pre-fail Always
- 3080
4 Start_Stop_Count 0x0032 094 094 000 Old_age Always
- 6517
5 Reallocated_Sector_Ct 0x0033 252 252 010 Pre-fail Always
- 0
7 Seek_Error_Rate 0x002e 252 252 051 Old_age Always
- 0
8 Seek_Time_Performance 0x0024 252 252 015 Old_age Offline
- 0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always
- 8503
10 Spin_Retry_Count 0x0032 252 252 051 Old_age Always
- 0
11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always
- 738
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always
- 212
191 G-Sense_Error_Rate 0x0022 100 100 000 Old_age Always
- 2
192 Power-Off_Retract_Count 0x0022 252 252 000 Old_age Always
- 0
194 Temperature_Celsius 0x0002 046 046 000 Old_age Always
- 54 (Min/Max 21/60)
195 Hardware_ECC_Recovered 0x003a 100 100 000 Old_age Always
- 0
196 Reallocated_Event_Count 0x0032 252 252 000 Old_age Always
- 0
197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always
- 28
198 Offline_Uncorrectable 0x0030 252 252 000 Old_age Offline
- 0
199 UDMA_CRC_Error_Count 0x0036 200 200 000 Old_age Always
- 0
200 Multi_Zone_Error_Rate 0x002a 100 100 000 Old_age Always
- 27
223 Load_Retry_Count 0x0032 100 100 000 Old_age Always
- 738
225 Load_Cycle_Count 0x0032 001 001 000 Old_age Always
- 7199202
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
Note: selective self-test log revision number (0) not 1 implies that no
selective self-test has ever been run
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been
run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Completed [00% left] (0-65535)
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
--
ubuntu-ru mailing list
ubuntu-ru@lists.ubuntu.com
https://lists.ubuntu.com/mailman/listinfo/ubuntu-ru