I would like to point out that the fix mentioned in upstream bug only
addresses less problematic part of this issue (bug 62625), but does not
fix the root cause of this bug or implement a workaround for it. This is
why the upstream bug is not closed yet.

We need to document the workaround for the users of problematic HW that is 
exposed to remaining_time bug. The workaround is to change gnome-power-manager 
config to use percentage charged instead of remaining time for automatic 
actions. See my previous comment regarding that.
I think this should go in release notes of Edgy.

If we are overly concerned by this behaviour (as Greg is in previous
post), we could reconsider changing default value in gconf for this and
use percentage charged as default.

-- 
Dual / Two Batteries, shutdown on empty expansion battery. (GPM does not 
recognises second battery on hotplug)
https://launchpad.net/bugs/60442

-- 