*** This bug is a duplicate of bug 194719 ***
    https://bugs.launchpad.net/bugs/194719

I can confirm this on a Thinkpad T43p after updating last night.  For
me, its stuck at:

Computer is running on battery power.
Laptop battery fully charged (99%)
Battery charge time is currently unknown

If I plug in, I can get it to say Computer is plugged in, charging, etc,
but still no battery state and always at 99%.  Addtionally, the tray
icon is always the "I'm plugged in and fully charged" icon.

uname -a: Linux euler 2.6.24-8-generic #1 SMP Thu Feb 14 20:40:45 UTC
2008 i686 GNU/Linux

dpkg -l | grep gnome-power-manager: 2.21.1-0ubuntu1

cat /proc/acpi/battery/BAT0/*:

alarm:                   3263 mWh
present:                 yes
design capacity:         77750 mWh
last full capacity:      65260 mWh
battery technology:      rechargeable
design voltage:          10800 mV
design capacity warning: 3263 mWh
design capacity low:     200 mWh
capacity granularity 1:  1 mWh
capacity granularity 2:  1 mWh
model number:            IBM-92P1068
serial number:            1799
battery type:            LION
OEM info:                Panasonic
present:                 yes
capacity state:          ok
charging state:          discharging
present rate:            19455 mW
remaining capacity:      54670 mWh
present voltage:         11777 mV


lshal output is attached.


** Attachment added: "lshal_output"
   http://launchpadlibrarian.net/12156766/lshal_output

-- 
gnome-power-manager does not work as expected after updates. (Hardy)
https://bugs.launchpad.net/bugs/194263
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.

-- 
ubuntu-bugs mailing list
ubuntu-bugs@lists.ubuntu.com
https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs