Just in case, have you tried hdparm -B 254 /dev/hda instead of 255, ie
just in case the reported load cycle count of 4073 is not a correct
representation? I think the last figure in each line is left up to the
drive manufacturer to define (eg one of my drive's "temperature celcius"
readings from smartctl reports as 906887219).

Buried way deep in bug 59695, someone pointed out that 255 isn't an
officially defined setting. 255 doesn't make any difference to load
cycles frequency on my drive, but 254 sure does.

-- 
Persistent laptop drive clicking in kernels since 2006
https://bugs.launchpad.net/bugs/164721
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.

-- 
ubuntu-bugs mailing list
ubuntu-bugs@lists.ubuntu.com
https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs

Reply via email to