Tested mutter 50.1-0ubuntu2.5 from resolute-proposed (libmutter-18-0,
gir1.2-mutter-18, mutter-common, mutter-common-bin) on Ubuntu 26.04.1 LTS,
GNOME Shell 50.1, Wayland, two identical 1920x1080 monitors on AMD iGPU.

Before (50.1-0ubuntu2.4): a maximized window moved with Super+Shift+Left
jumped back to the original monitor after Alt+Tab away and back (or
Super+<num>). Reproducible with every app.

After (50.1-0ubuntu2.5): maximized windows moved with Super+Shift+Arrow
stay maximized on the target monitor after Alt+Tab / Super+<num> focus
changes. Tested with several apps.

Note: in my setup it reproduced with just two monitors (primary + one
external), not only with two extra monitors as in the test plan.

-- 
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/2147214

Title:
  Maximized windows moved by Shift+Super+Arrow get moved back when focus
  is lost

To manage notifications about this bug go to:
https://bugs.launchpad.net/mutter/+bug/2147214/+subscriptions


-- 