Public bug reported:

My it8718 chip measures voltages, fan RPM and temperatures. I want to
monitor what sensors.conf calls temp1, labelled "NBr Temp". I can set
that up via the GUI and it works. But when I log out and back in or
restart the Xfce panel, that shows +3.3V instead, which is in2 in
sensors.conf. Furthermore, the label for in2 becomes "NBr Temp".
Initially, before I tried to monitor "NBr Temp", that label was
correctly displayed.

This started working properly after I built xfce-sensors-plugin 1.3.92
from https://git.xfce.org/panel-plugins/xfce4-sensors-plugin/

This may be the bug, now fixed over there:
https://bugzilla.xfce.org/show_bug.cgi?id=14398

ProblemType: Bug
DistroRelease: Ubuntu 20.04
Package: xfce4-sensors-plugin 1.3.0-2build1
ProcVersionSignature: Ubuntu 5.4.0-29.33-generic 5.4.30
Uname: Linux 5.4.0-29-generic x86_64
NonfreeKernelModules: nvidia_modeset nvidia
ApportVersion: 2.20.11-0ubuntu27
Architecture: amd64
CasperMD5CheckResult: skip
CurrentDesktop: XFCE
Date: Sun May 10 11:23:05 2020
SourcePackage: xfce4-sensors-plugin
UpgradeStatus: Upgraded to focal on 2020-04-06 (34 days ago)

** Affects: xfce4-sensors-plugin (Ubuntu)
     Importance: Undecided
         Status: New


** Tags: amd64 apport-bug focal

-- 
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/1877873

Title:
  Temperature becomes voltage after restarting panel

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/xfce4-sensors-plugin/+bug/1877873/+subscriptions

-- 
ubuntu-bugs mailing list
ubuntu-bugs@lists.ubuntu.com
https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs

Reply via email to