I can not reproduce the problem, I see SQL has used 'compute_nodes.deleted = 0' to filter deleted services as the following debug info shows (mitaka).
(Pdb) <oslo_db.sqlalchemy.orm.Query object at 0x7f97672b9810> (Pdb) 'SELECT count(compute_nodes.id) AS count_1, sum(compute_nodes.vcpus) AS sum_1, sum(compute_nodes.memory_mb) AS sum_2, sum(compute_nodes.local_gb) AS sum_3, sum(compute_nodes.vcpus_used) AS sum_4, sum(compute_nodes.memory_mb_used) AS sum_5, sum(compute_nodes.local_gb_used) AS sum_6, sum(compute_nodes.free_ram_mb) AS sum_7, sum(compute_nodes.free_disk_gb) AS sum_8, sum(compute_nodes.current_workload) AS sum_9, sum(compute_nodes.running_vms) AS sum_10, sum(compute_nodes.disk_available_least) AS sum_11 \nFROM compute_nodes, services \nWHERE compute_nodes.deleted = :deleted_1 AND services.disabled = 0 AND services."binary" = :binary_1 AND (services.host = compute_nodes.host OR services.id = compute_nodes.service_id)' This is result I run above SQL in mysql directly, all are OK. mysql> SELECT count(compute_nodes.id) AS count_1, sum(compute_nodes.vcpus) AS sum_1, sum(compute_nodes.memory_mb) AS sum_2, sum(compute_nodes.local_gb) AS sum_3, sum(compute_nodes.vcpus_used) AS sum_4, sum(compute_nodes.memory_mb_used) AS sum_5, sum(compute_nodes.local_gb_used) AS sum_6, sum(compute_nodes.free_ram_mb) AS sum_7, sum(compute_nodes.free_disk_gb) AS sum_8, sum(compute_nodes.current_workload) AS sum_9, sum(compute_nodes.running_vms) AS sum_10, sum(compute_nodes.disk_available_least) AS sum_11 FROM compute_nodes, services WHERE compute_nodes.deleted = 0 AND services.disabled = 0 AND services.binary = 'nova-compute' AND (services.host = compute_nodes.host OR services.id = compute_nodes.service_id); +---------+-------+-------+-------+-------+-------+-------+-------+-------+-------+--------+--------+ | count_1 | sum_1 | sum_2 | sum_3 | sum_4 | sum_5 | sum_6 | sum_7 | sum_8 | sum_9 | sum_10 | sum_11 | +---------+-------+-------+-------+-------+-------+-------+-------+-------+-------+--------+--------+ | 2 | 4 | 7902 | 76 | 0 | 1024 | 0 | 6878 | 76 | 0 | 0 | 72 | +---------+-------+-------+-------+-------+-------+-------+-------+-------+-------+--------+--------+ 1 row in set (0.00 sec) mysql> SELECT sum(compute_nodes.vcpus) FROM compute_nodes, services WHERE compute_nodes.deleted = 0 AND services.disabled = 0 AND services.binary = 'nova-compute' AND (services.host = compute_nodes.host OR services.id = compute_nodes.service_id); +--------------------------+ | sum(compute_nodes.vcpus) | +--------------------------+ | 4 | +--------------------------+ 1 row in set (0.00 sec) Below are steps I used to create test env: 1, There are 3 nova-compute nodes initially. 2, Then use 'openstack compute service delete 10' to delete one compute service. 3, 'select * from services where id=10' will show deleted field of this record is not 0 no longer. -- You received this bug notification because you are a member of Ubuntu Bugs, which is subscribed to Ubuntu. https://bugs.launchpad.net/bugs/1719770 Title: hypervisor stats issue after charm removal if nova-compute service not disabled first To manage notifications about this bug go to: https://bugs.launchpad.net/charm-nova-compute/+bug/1719770/+subscriptions -- ubuntu-bugs mailing list [email protected] https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs