Ok, its caused by dialer_app.tests.test_calls.TestCalls.test_incoming

What happens:
* autopilot starts the dialer-app (by system call "/usr/bin/dialer-app 
--desktop_file_hint=/usr/share/applications/dialer-app.desktop")
* autopilot triggers the incoming call notification and accepts the call
* this causes telephony-service to upstart-app-launch the following url: 
application:///dialer-app.desktop
* upstart-app-launch doesn't really know about the "manually" launched instance 
and tries to launch it a second time
* unity8 in turn does reject it because there is already one session for this 
app

this is not an issue if all instances are launched via upstart-app-
launch (hence doesn't happen in real-world scenario)

So I guess the solution is to use upstart-app-launch in dialer-app's
autopilot tests.

-- 
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/1297900

Title:
  crash QUbuntu: Could not create application instance

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/qtubuntu/+bug/1297900/+subscriptions

-- 