Public bug reported: xoscope crashes on changing the time/division if there is a channel showing the math function "Diff 1-2"
If a channel is set to the math function "Diff 1-2" and you raise the time/division (pressing 9) several times eg. 3 or 4 xoscope exits with a segment fault. In some other times (with same conditions) it stops responding and I have to close it with ctrl+c ^C in this case it shows an error with malloc() function. I don't have any problems if I first set the time/division to it's maximum (2000ms/div) and after that I set the channel to show the "Diff 1-2" function. Some information: artis@ubuntu:~$ dpkg --list | egrep xos ii xoscope 2.0-3.1ubuntu3 amd64 digital oscilloscope artis@ubuntu:~$ apt-cache policy xoscope xoscope: Instaŀlat: 2.0-3.1ubuntu3 Candidat: 2.0-3.1ubuntu3 Taula de versió: *** 2.0-3.1ubuntu3 0 500 http://archive.ubuntu.com/ubuntu/ saucy/universe amd64 Packages 100 /var/lib/dpkg/status artis@ubuntu:~$ lsb_release -rd Description: Ubuntu 13.10 Release: 13.10 I also will add as attachment some outputs of xoscope to the terminal. ** Affects: xoscope (Ubuntu) Importance: Undecided Status: New ** Attachment added: "xoscope output to terminal" https://bugs.launchpad.net/bugs/1269523/+attachment/3949578/+files/xoscope_bug.txt -- You received this bug notification because you are a member of Ubuntu Bugs, which is subscribed to Ubuntu. https://bugs.launchpad.net/bugs/1269523 Title: xoscope crashes on changing the time/division if there is a chennel showing the math function "Diff 1-2" To manage notifications about this bug go to: https://bugs.launchpad.net/ubuntu/+source/xoscope/+bug/1269523/+subscriptions -- ubuntu-bugs mailing list ubuntu-bugs@lists.ubuntu.com https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs