Note :

I got rid off the autosave.db, preventing first time simple-scan to
launch quickly.

I updated to simple-scan latest version. Simple Scan 3.11.3, released on
2013-12-18.

Still experiencing same issue : impossible to scan multiple pages in a
row via the scan all pages in feeder feature.

log collected via simple-scan -d :

simple-scan -d
[+0.00s] DEBUG: simple-scan.vala:582: Starting Simple Scan 3.11.3, PID=22785
[+0.00s] DEBUG: Connecting to session manager
[+0.06s] DEBUG: ui.vala:1638: Restoring window to 600x400 pixels
[+0.06s] DEBUG: ui.vala:1643: Restoring window to maximized
[+0.06s] DEBUG: autosave-manager.vala:64: Loading autosave information
[+0.06s] DEBUG: autosave-manager.vala:258: Waiting to autosave...
[+0.06s] WARNING: autosave-manager.vala:76: Could not load autosave infomation; 
not restoring any autosaves
[+0.11s] DEBUG: scanner.vala:1443: sane_init () -> SANE_STATUS_GOOD
[+0.11s] DEBUG: scanner.vala:1449: SANE version 1.0.23
[+0.11s] DEBUG: scanner.vala:1510: Requesting redetection of scan devices
[+0.11s] DEBUG: scanner.vala:802: Processing request
[+0.24s] DEBUG: autosave-manager.vala:280: Autosaving book information
[+2.81s] DEBUG: scanner.vala:338: sane_get_devices () -> SANE_STATUS_GOOD
[+2.81s] DEBUG: scanner.vala:350: Device: 
name="hpaio:/usb/Officejet_6300_series?serial=CN814FB1Y304J5" 
vendor="Hewlett-Packard" model="Officejet_6300_series" type="all-in-one"
[+21.11s] DEBUG: simple-scan.vala:310: Requesting scan at 300 dpi from device 
'hpaio:/usb/Officejet_6300_series?serial=CN814FB1Y304J5'
[+21.11s] DEBUG: scanner.vala:1556: Scanner.scan 
("hpaio:/usb/Officejet_6300_series?serial=CN814FB1Y304J5", dpi=300, 
scan_mode=ScanMode.COLOR, depth=8, type=ScanType.ADF_BOTH, paper_width=0, 
paper_height=0, brightness=0, contrast=0)
[+21.11s] DEBUG: scanner.vala:802: Processing request
[+23.22s] DEBUG: scanner.vala:863: sane_open 
("hpaio:/usb/Officejet_6300_series?serial=CN814FB1Y304J5") -> SANE_STATUS_GOOD
[+23.22s] DEBUG: scanner.vala:884: sane_get_option_descriptor (0)
[+23.22s] DEBUG: scanner.vala:734: Option 0: title='Number of options' type=int 
size=4 cap=,soft-detect
[+23.22s] DEBUG: scanner.vala:737:   Description: Read-only option that 
specifies how many options a specific devices supports.
[+23.22s] DEBUG: scanner.vala:884: sane_get_option_descriptor (1)
[+23.22s] DEBUG: scanner.vala:734: Option 1: name='(null)' title='Scan mode' 
type=group size=0
[+23.22s] DEBUG: scanner.vala:884: sane_get_option_descriptor (2)
[+23.22s] DEBUG: scanner.vala:734: Option 2: name='mode' title='Scan mode' 
type=string size=20 values=["Lineart", "Gray", "Color"] 
cap=,soft-select,soft-detect
[+23.22s] DEBUG: scanner.vala:737:   Description: Selects the scan mode (e.g., 
lineart, monochrome, or color).
[+23.22s] DEBUG: scanner.vala:884: sane_get_option_descriptor (3)
[+23.22s] DEBUG: scanner.vala:734: Option 3: name='resolution' title='Scan 
resolution' type=int size=4 unit=dpi values=[75, 100, 150, 200, 300, 600] 
cap=,soft-select,soft-detect
[+23.22s] DEBUG: scanner.vala:737:   Description: Sets the resolution of the 
scanned image.
[+23.22s] DEBUG: scanner.vala:884: sane_get_option_descriptor (4)
[+23.22s] DEBUG: scanner.vala:734: Option 4: name='(null)' title='Advanced' 
type=group size=0 cap=,advanced
[+23.22s] DEBUG: scanner.vala:884: sane_get_option_descriptor (5)
[+23.22s] DEBUG: scanner.vala:734: Option 5: name='contrast' title='Contrast' 
type=int size=4 min=-127, max=127, quant=0 cap=,soft-select,soft-detect,advanced
[+23.22s] DEBUG: scanner.vala:737:   Description: Controls the contrast of the 
acquired image.
[+23.22s] DEBUG: scanner.vala:884: sane_get_option_descriptor (6)
[+23.22s] DEBUG: scanner.vala:734: Option 6: name='brightness' 
title='Brightness' type=int size=4 min=-127, max=127, quant=0 
cap=,soft-select,soft-detect,advanced
[+23.22s] DEBUG: scanner.vala:737:   Description: Controls the brightness of 
the acquired image.
[+23.22s] DEBUG: scanner.vala:884: sane_get_option_descriptor (7)
[+23.22s] DEBUG: scanner.vala:734: Option 7: name='compression' 
title='Compression' type=string size=20 values=["None", "JPEG"] 
cap=,soft-select,soft-detect,advanced
[+23.22s] DEBUG: scanner.vala:737:   Description: Selects the scanner 
compression method for faster scans, possibly at the expense of image quality.
[+23.22s] DEBUG: scanner.vala:884: sane_get_option_descriptor (8)
[+23.22s] DEBUG: scanner.vala:734: Option 8: name='jpeg-quality' title='JPEG 
compression factor' type=int size=4 min=0, max=100, quant=0 
cap=,soft-select,soft-detect,advanced
[+23.22s] DEBUG: scanner.vala:737:   Description: Sets the scanner JPEG 
compression factor. Larger numbers mean better compression, and smaller numbers 
mean better image quality.
[+23.22s] DEBUG: scanner.vala:884: sane_get_option_descriptor (9)
[+23.22s] DEBUG: scanner.vala:734: Option 9: name='batch-scan' title='Batch 
scan' type=bool size=4 cap=,soft-select,soft-detect,advanced
[+23.22s] DEBUG: scanner.vala:737:   Description: Enables continuous scanning 
with automatic document feeder (ADF).
[+23.22s] DEBUG: scanner.vala:884: sane_get_option_descriptor (10)
[+23.22s] DEBUG: scanner.vala:734: Option 10: name='source' title='Scan source' 
type=string size=20 values=["Auto", "Flatbed", "ADF"] 
cap=,soft-select,soft-detect,advanced
[+23.22s] DEBUG: scanner.vala:737:   Description: Selects the scan source (such 
as a document-feeder).
[+23.22s] DEBUG: scanner.vala:884: sane_get_option_descriptor (11)
[+23.22s] DEBUG: scanner.vala:734: Option 11: name='duplex' title='Duplex' 
type=bool size=4 cap=,soft-select,soft-detect,advanced
[+23.22s] DEBUG: scanner.vala:737:   Description: Enables scanning on both 
sides of the page.
[+23.22s] DEBUG: scanner.vala:884: sane_get_option_descriptor (12)
[+23.22s] DEBUG: scanner.vala:734: Option 12: name='(null)' title='Geometry' 
type=group size=0 cap=,advanced
[+23.22s] DEBUG: scanner.vala:884: sane_get_option_descriptor (13)
[+23.22s] DEBUG: scanner.vala:734: Option 13: name='length-measurement' 
title='Length measurement' type=string size=20 values=["Unknown", 
"Approximate", "Padded"] cap=,soft-select,soft-detect,advanced
[+23.22s] DEBUG: scanner.vala:737:   Description: Selects how the scanned image 
length is measured and reported, which is impossible to know in advance for 
scrollfed scans.
[+23.22s] DEBUG: scanner.vala:884: sane_get_option_descriptor (14)
[+23.22s] DEBUG: scanner.vala:734: Option 14: name='tl-x' title='Top-left x' 
type=fixed size=4 unit=mm min=0.000000, max=215.899994, quant=0 
cap=,soft-select,soft-detect
[+23.22s] DEBUG: scanner.vala:737:   Description: Top-left x position of scan 
area.
[+23.22s] DEBUG: scanner.vala:884: sane_get_option_descriptor (15)
[+23.22s] DEBUG: scanner.vala:734: Option 15: name='tl-y' title='Top-left y' 
type=fixed size=4 unit=mm min=0.000000, max=381.000000, quant=0 
cap=,soft-select,soft-detect
[+23.22s] DEBUG: scanner.vala:737:   Description: Top-left y position of scan 
area.
[+23.22s] DEBUG: scanner.vala:884: sane_get_option_descriptor (16)
[+23.22s] DEBUG: scanner.vala:734: Option 16: name='br-x' title='Bottom-right 
x' type=fixed size=4 unit=mm min=0.000000, max=215.899994, quant=0 
cap=,soft-select,soft-detect
[+23.22s] DEBUG: scanner.vala:737:   Description: Bottom-right x position of 
scan area.
[+23.22s] DEBUG: scanner.vala:884: sane_get_option_descriptor (17)
[+23.22s] DEBUG: scanner.vala:734: Option 17: name='br-y' title='Bottom-right 
y' type=fixed size=4 unit=mm min=0.000000, max=381.000000, quant=0 
cap=,soft-select,soft-detect
[+23.22s] DEBUG: scanner.vala:737:   Description: Bottom-right y position of 
scan area.
[+23.22s] DEBUG: scanner.vala:884: sane_get_option_descriptor (18)
[+23.22s] DEBUG: scanner.vala:546: sane_control_option (10, 
SANE_ACTION_SET_VALUE, "ADF") -> (SANE_STATUS_GOOD, "ADF")
[+23.22s] DEBUG: scanner.vala:546: sane_control_option (2, 
SANE_ACTION_SET_VALUE, "Color") -> (SANE_STATUS_GOOD, "Color")
[+23.22s] DEBUG: scanner.vala:425: sane_control_option (11, 
SANE_ACTION_SET_VALUE, SANE_TRUE) -> (SANE_STATUS_GOOD, SANE_TRUE)
[+23.22s] DEBUG: scanner.vala:425: sane_control_option (9, 
SANE_ACTION_SET_VALUE, SANE_TRUE) -> (SANE_STATUS_GOOD, SANE_TRUE)
[+23.22s] DEBUG: scanner.vala:546: sane_control_option (7, 
SANE_ACTION_SET_VALUE, "None") -> (SANE_STATUS_GOOD, "None")
[+23.22s] DEBUG: scanner.vala:462: sane_control_option (3, 
SANE_ACTION_SET_VALUE, 300) -> (SANE_STATUS_GOOD, 300)
[+23.22s] DEBUG: scanner.vala:530: sane_control_option (16, 
SANE_ACTION_SET_VALUE, option.range.max) -> (SANE_STATUS_GOOD)
[+23.22s] DEBUG: scanner.vala:530: sane_control_option (17, 
SANE_ACTION_SET_VALUE, option.range.max) -> (SANE_STATUS_GOOD)
[+69.08s] DEBUG: scanner.vala:1209: sane_start (page=0, pass=0) -> 
SANE_STATUS_IO_ERROR
[+69.08s] WARNING: scanner.vala:1216: Unable to start device: Error during 
device I/O
[+69.08s] DEBUG: scanner.vala:764: sane_cancel ()
[+71.08s] DEBUG: scanner.vala:767: sane_close ()

-- 
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/1266310

Title:
  impossible to scan all pages from feeder with HP OfficeJet 6310

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/simple-scan/+bug/1266310/+subscriptions

-- 
ubuntu-bugs mailing list
ubuntu-bugs@lists.ubuntu.com
https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs

Reply via email to