This bug was fixed in the package xdiagnose - 3.4 --------------- xdiagnose (3.4) raring; urgency=low
* bin/xrotate: Add new script to manually rotate screen and input. Designed for the Nexus 7 tablet; will need extended to support other devices. * bin/xedid: Add new script for viewing and installing EDID files into firmware. + Fixes situation where EDID is unavailable, corrupted, or invalid (LP: #575985) + Fixes situation where KVM corrupts the EDID the monitor provides. (LP: #992346) * bin/xpci: Fix two string issues so xpci will run. (LP: #1098390) * apport/source_xorg.py: Gracefully skip Xorg.0.log parsing if the parsing fails. (LP: #1098395) * apport/apport-gpu-error-intel.py: Gracefully skip DMI parsing if the parsing fails. (LP: #1062042) * xdiagnose/applet.py: Fix bug where a stray =1 gets added to GRUB_CMDLINE_LINUX_DEFAULT. (LP: #954123) * tests: Add sample Xorg.*.log files rather than using the on-disk one -- Bryce Harrington <br...@ubuntu.com> Wed, 09 Jan 2013 18:17:24 -0800 ** Changed in: xdiagnose (Ubuntu) Status: Triaged => Fix Released -- You received this bug notification because you are a member of Ubuntu Bugs, which is subscribed to Ubuntu. https://bugs.launchpad.net/bugs/954123 Title: xdiagnose put plymouth:debug=1=1 into config To manage notifications about this bug go to: https://bugs.launchpad.net/ubuntu/+source/xdiagnose/+bug/954123/+subscriptions -- ubuntu-bugs mailing list ubuntu-bugs@lists.ubuntu.com https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs