in the function up_device_supply_refresh_battery in the file up-device-supply.c there is a suspicious line /* only disable the polling if the kernel tells us we're fully charged, not if we've guessed the state to be fully charged */ supply->priv->enable_poll = (state != UP_DEVICE_STATE_FULLY_CHARGED);
I feel that this disables the polling of the battery, this together with the delayed report that the battery is discharging could lead to the error we see but i do not know the code so i cannot be sure. I also do not know how to build my own upowerd so that i can test this. -- You received this bug notification because you are a member of Ubuntu Bugs, which is subscribed to Ubuntu. https://bugs.launchpad.net/bugs/467825 Title: Battery state always "fully charged" To manage notifications about this bug go to: https://bugs.launchpad.net/gnome-power/+bug/467825/+subscriptions -- ubuntu-bugs mailing list ubuntu-bugs@lists.ubuntu.com https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs