in the function 
up_device_supply_refresh_battery 
in the file up-device-supply.c
there is a suspicious line
        /* only disable the polling if the kernel tells us we're fully charged,
           not if we've guessed the state to be fully charged */
        supply->priv->enable_poll = (state != UP_DEVICE_STATE_FULLY_CHARGED);

I feel that this disables the polling of the battery, this together with the 
delayed report that the battery is discharging could lead to the error we see 
but i do not know the code so i cannot be sure. 
I also do not know how to build my own upowerd so that i can test this.

-- 
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/467825

Title:
  Battery state always "fully charged"

To manage notifications about this bug go to:
https://bugs.launchpad.net/gnome-power/+bug/467825/+subscriptions

-- 