Hi, now I have a working 10.04 + evdev driver, there are a few problems but works.
I started with a fresh ubuntu lucid install and: - I added usbhid.quirks=0xeef:0x1:0x40 to /etc/default/grub, change line: GRUB_CMDLINE_LINUX_DEFAULT="quiet splash" to GRUB_CMDLINE_LINUX_DEFAULT="quiet splash usbhid.quirks=0xeef:0x1:0x40" - Blacklisted usbtouchscreen module, add: blacklist usbtouchscreen to /etc/modprobe.d/blacklist.conf - Next I installed all neccesary deps to proper compile xinput calibrator (download here: http://github.com/tias/xinput_calibrator/downloads ): $ sudo apt-get install build-essential libgtkmm-2.4-dev autoconf libtool - After extract xinput files from the tgz/zip, enter to the decompressed directory and type: $ ./autogen.sh $ ./configure $ make $ sudo make install (optional, binary files are into ../src/ dir ) Here starts my problem, I want to calibrate the device but there are 2 listed into xinput list. After finding the right one with xinput test "id" I can get the correct values for the calibration, but I can only apply with this: $ xinput set-int-prop "id from the right device" "Evdev Axes Swap" 8 1 #<-You probably doesn't need to do this $ xinput set-int-prop "id from the right device" "Evdev Axis Calibration" 32 315 3902 337 3842 The id's changes every boot, and I can't apply the same configuration. Also I tried adding the udev rules, but do not worked for me. Ernesto, you have luck with udev rules? lucid comes with evdev 2.3.2, this version supports udev rules? Thanks. -- eGalax touchscreen configured as tablet https://bugs.launchpad.net/bugs/549447 You received this bug notification because you are a member of Ubuntu Bugs, which is subscribed to Ubuntu. -- ubuntu-bugs mailing list ubuntu-bugs@lists.ubuntu.com https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs