Confirmed on Hardy, with Acer Travelmate,  wont even report accurate 
time/percent. but the output of acpi -b *does* report with complete accuracy 
every time I manually execute it.
Also percent remaining differs vastly on mouse-over to click on, does not 
update itself for most of the time, once minute its 98 percent then some time 
later it changes to 43% then its 18 then its whatever, no set pattern, it might 
never show 43 but show 71 then 0, even when it reports percent critical and 
action level, it does not turn off/hibernate or do anything, no pop up balloon, 
runs until battery exhausted. This WORKED fine on Windows XP and Fedora, but I 
wiped Fedora for Ubuntu.

anyway.....
/proc/acpi/battery/BAT0/
      info:
present:                 yes
design capacity:         65120 mWh
last full capacity:      52810 mWh
battery technology:      rechargeable
design voltage:          14800 mV
design capacity warning: unknown
design capacity low:     unknown
capacity granularity 1:  unknown
capacity granularity 2:  unknown
model number:            02ZL
serial number:           0
battery type:            LION
OEM info:                PS

     alarm:
unsupported
      state:
present:                 yes
capacity state:          ok
charging state:          discharging
present rate:            12026 mW
remaining capacity:      18120 mWh
present voltage:         14433 mV


acpi -b
Battery 1: discharging, 35%,  01:29:58 remaining                   panel icon 
shows 71 and 11 hours remaining (I only wish) :)


** Attachment added: "hal-eddie.txt"
   http://launchpadlibrarian.net/18936057/hal-eddie.txt

-- 
Gnome Battery Charge Monitor not giving estimated time remaining
https://bugs.launchpad.net/bugs/38795
You received this bug notification because you are a member of Ubuntu
Bugs, which is a direct subscriber.

-- 
ubuntu-bugs mailing list
ubuntu-bugs@lists.ubuntu.com
https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs

Reply via email to