On 20/07/2012 16:24, Benoît Thébaudeau wrote: > Add support for Freescale's i.MX DryIce RTC, present on i.MX25. > > Signed-off-by: Benoît Thébaudeau <benoit.thebaud...@advansee.com> > Cc: Wolfgang Denk <w...@denx.de> > Cc: Stefano Babic <sba...@denx.de> > ---
Hi Benoit, just a few comments. > + > +/* > + * Date & Time support for Freescale i.MX DryIce RTC > + */ > + > +#include <common.h> > +#include <command.h> > +#include <rtc.h> > + > +#if defined(CONFIG_CMD_DATE) > + > +#include <asm/io.h> > +#include <asm/arch/imx-regs.h> > + > +/* DryIce Register Definitions */ > + > +#define DTCMR 0x00 /* Time Counter MSB Reg */ > +#define DTCLR 0x04 /* Time Counter LSB Reg */ > + > +#define DCAMR 0x08 /* Clock Alarm MSB Reg */ > +#define DCALR 0x0c /* Clock Alarm LSB Reg */ U-Boot as rule does not allow usage of start address + offset to access internal registers. Instead of that, please define a proper C structure with the register's layout. This should be fixed globally for all read / write accesses. > +/* > + * This function attempts to clear the dryice write-error flag. > + * > + * A dryice write error is similar to a bus fault and should not occur in > + * normal operation. Clearing the flag requires another write, so the root > + * cause of the problem may need to be fixed before the flag can be cleared. > + */ > +static void clear_write_error(void) > +{ > + int cnt; > + > + puts("### Warning: RTC - Register write error!\n"); > + > + /* clear the write error flag */ > + __raw_writel(DSR_WEF, IMX_DRYICE_BASE + DSR); Ditto > +int rtc_get(struct rtc_time *tmp) > +{ > + unsigned long now; > + int rc; > + > + rc = di_init(); Why is di_init always called ? Should be not checked if it is was already initialized and the function should be called only once ? Best regards, Stefano Babic -- ===================================================================== DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: +49-8142-66989-53 Fax: +49-8142-66989-80 Email: sba...@denx.de ===================================================================== _______________________________________________ U-Boot mailing list U-Boot@lists.denx.de http://lists.denx.de/mailman/listinfo/u-boot