Hello Thomas, I just debugging some usb issues on an dm365 based board. I noticed that if no usb device is connected to the board, the "usb start" command does have a long timeout (also have access to an dm365evm board, same behaviour). Found the reason for this big timeout here:
./drivers/usb/musb/musb_hcd.c usb_lowlevel_init(): timeout = musb_cfg.timeout; while (timeout--) if (readb(&musbr->devctl) & MUSB_DEVCTL_HM) break; with ./drivers/usb/musb/davinci.: /* MUSB platform configuration */ struct musb_config musb_cfg = { .regs = (struct musb_regs *)MENTOR_USB0_BASE, .timeout = DAVINCI_USB_TIMEOUT, .musb_speed = 0, }; and ./drivers/usb/musb/davinci.h: #define DAVINCI_USB_TIMEOUT 0x3FFFFFF Why is this DAVINCI_USB_TIMEOUT value so high? This could be shorter, or are there some reasons for such a long timeout? Thanks! bye, Heiko -- DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany _______________________________________________ U-Boot mailing list U-Boot@lists.denx.de http://lists.denx.de/mailman/listinfo/u-boot