Hi OLivier On 1/3/23 18:08, Patrick DELAUNAY wrote: > Hi, > > On 12/15/22 13:51, Olivier Moysan wrote: >> Add support of offset and linear calibration for STM32MP15. >> The calibration is performed once at probe. The ADC is set in power on >> state for calibration. It remains in this state after calibration, >> to give to the kernel the opportunity to retrieve calibration data, >> directly from the ADC. >> >> Signed-off-by: Olivier Moysan <olivier.moy...@foss.st.com> >> --- >> >> drivers/adc/stm32-adc.c | 134 ++++++++++++++++++++++++++++++++++------ >> 1 file changed, 116 insertions(+), 18 deletions(-) >> > > > Reviewed-by: Patrick Delaunay <patrick.delau...@foss.st.com> > > Thanks > Patrick >
Applied on u-boot-stm32/master Thanks