> Set default critical/alert temperature and enabling monoitoring. > Without calling imx_tmu_enable_msite() monitoring will not be enabled > and read_temperature will return 0. Additionally without setting alert > temperature will cause imx_tmu_get_temp() to spin indefiniately thinking > the system needs to cool. > This resolves the board spinning endlessly when enabling IMX_TMU in the > SPL. > Reviewed-by: Fabio Estevam <feste...@gmail.com> > Signed-off-by: Tim Harvey <thar...@gateworks.com> Applied to u-boot-imx, master, thanks !
Best regards, Stefano Babic -- ===================================================================== DENX Software Engineering GmbH, Managing Director: Wolfgang Denk HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: +49-8142-66989-53 Fax: +49-8142-66989-80 Email: sba...@denx.de =====================================================================