OF graph endpoint connections must be bidirectional and dtc warn if they
are not. i.MX7 based DTs have an error and generate
warnings:

arch/arm/dts/imx7d-sdb.dtb: Warning (graph_endpoint):
/replicator/ports/port@0/endpoint: graph connection to node
'/soc/tpiu@30087000/port/endpoint' is not bidirectional
arch/arm/dts/imx7d-sdb.dtb: Warning (graph_endpoint):
/soc/tpiu@30087000/port/endpoint: graph connection to node
'/replicator/ports/port@1/endpoint' is not bidirectional

Signed-off-by: Ilko Iliev <il...@ronetix.at>
---
 arch/arm/dts/imx7s.dtsi | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/arch/arm/dts/imx7s.dtsi b/arch/arm/dts/imx7s.dtsi
index 5c2e98be06..967023fde1 100644
--- a/arch/arm/dts/imx7s.dtsi
+++ b/arch/arm/dts/imx7s.dtsi
@@ -323,7 +323,7 @@
                        port {
                                tpiu_in_port: endpoint {
                                        slave-mode;
-                                       remote-endpoint = 
<&replicator_out_port1>;
+                                       remote-endpoint = 
<&replicator_out_port0>;
                                };
                        };
                };
-- 
2.25.1