For automating testing we should be able to power off the test system.
The implementation of EFI_RESET_SHUTDOWN requires the do_poweroff()
function which is only available if CONFIG_CMD_POWEROFF=y.

Enable CONFIG_CMD_POWEROFF if PSCI reset is available.

Signed-off-by: Heinrich Schuchardt <xypron.g...@gmx.de>
---
 lib/efi_selftest/Kconfig | 1 +
 1 file changed, 1 insertion(+)

diff --git a/lib/efi_selftest/Kconfig b/lib/efi_selftest/Kconfig
index d20f5899af..478140330b 100644
--- a/lib/efi_selftest/Kconfig
+++ b/lib/efi_selftest/Kconfig
@@ -3,6 +3,7 @@ config CMD_BOOTEFI_SELFTEST
        depends on CMD_BOOTEFI
        imply FAT
        imply FAT_WRITE
+       imply CMD_POWEROFF if PSCI_RESET || SYSRESET_PSCI
        help
          This adds a UEFI test application to U-Boot that can be executed
          via the 'bootefi selftest' command. It provides extended tests of
--
2.24.1