Hi Stephen, On 4 October 2018 at 10:01, Stephen Warren <swar...@wwwdotorg.org> wrote: > On 10/01/2018 09:12 PM, Simon Glass wrote: >> >> From: Stephen Warren <swar...@nvidia.com> >> >> After a test has failed, test/py drains the U-Boot console log to ensure >> that any relevant output is captured. At this point, we don't care about >> detecting any additional errors, since the test is already known to have >> failed, and U-Boot will be restarted. To ensure that the test cleanup code >> is not interrupted, and can correctly terminate the log sections for the >> failed test, ignore any exception that occurs while reading the U-Boot >> console output during this limited period of time. > > > This probably shouldn't be in this series since I sent it separately as a > standalone patch a while ago.
Sorry about that. I picked it up and assumed it would fall out when I rebased to master, but I suppose your patch is not yet applied. Regards, Simon _______________________________________________ U-Boot mailing list U-Boot@lists.denx.de https://lists.denx.de/listinfo/u-boot