On Wed, Sep 13, 2017 at 02:58:48PM +0800, Wenyou Yang wrote:

> As said in 29.5.7 section of SAMA5D2 datasheet, before switching to
> the crystal oscillator, a check must be carried out to ensure that
> the oscillator is present and that its freqency is valid.
> 
> Signed-off-by: Wenyou Yang <[email protected]>
> Reviewed-by: Simon Glass <[email protected]>

Applied to u-boot/master, thanks!

-- 
Tom