On 09/04/2017 04:04 AM, Ran Wang wrote: > Low Frequency Periodic Signaling(LFPS) Peak-to-Peak Differential > Output Voltage Test Compliance fails using default transmitter > settings > > Change config of transmitter signal swings by setting register > PCSTXSWINGFULL to 0x47 to pass compliance tests. > > Signed-off-by: Sriram Dash <sriram.d...@nxp.com> > Signed-off-by: Rajesh Bhagat <rajesh.bha...@nxp.com> > Signed-off-by: Suresh Gupta <suresh.gu...@nxp.com> > Signed-off-by: Ran Wang <ran.wan...@nxp.com> > --- > Change in v5: > Use scfg_clrsetbits32() instead. > > Change in v4: > Update commit message about register setting. > Clean up the math in set_usb_pcstxswingfull(). > Rename USB_PCSTXSWINGFULL to SCFG_USB_PCSTXSWINGFULL. > > Change in v3: > Use inline function to make code cleaner. > Correct typo of 'CONFIG_ARCH_LS1043A'. > > Change in v2: > In function erratum_a008997(): > 1.Put a blank line after variable declaration.
Reordered Kconfig options. Applied to fsl-qoriq master. Thanks. York _______________________________________________ U-Boot mailing list U-Boot@lists.denx.de https://lists.denx.de/listinfo/u-boot