Hello Oleksandr,
Am 01.02.2017 um 19:52 schrieb Oleksandr Tymoshenko:
Tom Rini (tr...@konsulko.com) wrote:
On Tue, Jan 31, 2017 at 05:15:20PM -0800, Oleksandr Tymoshenko wrote:
Default fcr value is initialized in ns16550_serial_ofdata_to_platdata
but this function is only called if OF_CONTROL option is enabled while
the field is used whenever DM_SERIAL is set. So for configs that
do not have OF_CONTROL default fcr value is set to zero which leads
to loosing characters when serial port input is faster than reading
routine i.e. when copy-pasting long line to U-Boot prompt.
As a fix initialize fcr field in probe method
Signed-off-by: Oleksandr Tymoshenko <go...@bluezbox.com>
Cc: Marek Vasut <ma...@denx.de>
Cc: Tom Rini <tr...@konsulko.com>
Cc: Simon Glass <s...@chromium.org>
Are you still seeing this with v2017.03-rc1? Thanks!
No, this bug is not reproducible on v2017.03-rc1, I believe 17fa032671
fixed it. Not sure how I missed that patch I am pretty sure I tested my
BBB with master branch.
Yes commit 17fa032671 fixed this issue. How do you test? You must
type very fast, or copy&paste a long command ...
bye,
Heiko
--
DENX Software Engineering GmbH, Managing Director: Wolfgang Denk
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
_______________________________________________
U-Boot mailing list
U-Boot@lists.denx.de
http://lists.denx.de/mailman/listinfo/u-boot