On 03/13/2016 07:16 PM, Eric Anholt wrote:
For Raspberry Pi, we had the input clock rate to the pl011 fixed in
the rpi.c file, but it may be changed by firmware due to user changes
to config.txt.  Since the firmware always sets up the uart (default
115200 output unless the user changes it), we can just skip our own
uart init to simplify the boot process and more reliably get serial
output.

Tested-by: Stephen Warren <swar...@wwwdotorg.org>
# on RPi B+ and RPi 2