On Thu, Oct 08, 2015 at 11:31:47AM +0530, Lokesh Vutla wrote:

> On keystone2 Lamarr and Edison platforms, the PA clocksource
> mux in PLL REG1, can be changed only after enabling its clock
> domain.
> So selecting the output of PASS PLL as input to PA only after
> enabling the clockdomain.
> This is as per the debug done by "Vitaly Andrianov <vita...@ti.com>"
> and based on the previous work done by "Hao Zhang <hzh...@ti.com>"
> 
> Fixes: d634a0775bcf ("ARM: keystone2: Cleanup PLL init code")
> Reported-by: Vitaly Andrianov <vita...@ti.com>
> Tested-by: Vitaly Andrianov <vita...@ti.com>
> Signed-off-by: Lokesh Vutla <lokeshvu...@ti.com>

Applied to u-boot/master, thanks!

-- 
Tom

Attachment: signature.asc
Description: Digital signature

_______________________________________________
U-Boot mailing list
U-Boot@lists.denx.de
http://lists.denx.de/mailman/listinfo/u-boot

Reply via email to