On 23/01/2015 19:03, Soeren Moch wrote: > According to the i.MX6Q Reference Manual, clocks must be gated when > switching input clocks of async clock muxes. So use clock gates. Avoid > ldb_di0_ipu clock, because there is no clock gate for this signal. > > There have never been any complaints about problems with the old code, > but the new approach is in line with the recommendations in the manual. > > Signed-off-by: Soeren Moch <sm...@web.de> > -- > Cc: Stefano Babic <sba...@denx.de> > ---
Applied to u-boot-imx, thanks ! Best regards, Stefano Babic -- ===================================================================== DENX Software Engineering GmbH, Managing Director: Wolfgang Denk HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: +49-8142-66989-53 Fax: +49-8142-66989-80 Email: sba...@denx.de ===================================================================== _______________________________________________ U-Boot mailing list U-Boot@lists.denx.de http://lists.denx.de/mailman/listinfo/u-boot