Following commit "arm: omap3: Enable clocks for peripherals only if they are
used" (f33b9bd3984fb11e1d8566a866adc5957b1e1c9d) it is now necessary to enable
clocks for GPIO banks explicitly. On cm_t35, GPIO bank 5 is necessary for
scf0403 lcd support.

Enable GPIO bank 5 clocks.

Signed-off-by: Nikita Kiryanov <nik...@compulab.co.il>
Cc: Igor Grinberg <grinb...@compulab.co.il>
Cc: Tom Rini <tr...@ti.com>
---
 include/configs/cm_t35.h | 1 +
 1 file changed, 1 insertion(+)

diff --git a/include/configs/cm_t35.h b/include/configs/cm_t35.h
index e72187e..d5c1b9c 100644
--- a/include/configs/cm_t35.h
+++ b/include/configs/cm_t35.h
@@ -319,6 +319,7 @@
 
 /* Display Configuration */
 #define CONFIG_OMAP3_GPIO_2
+#define CONFIG_OMAP3_GPIO_5
 #define CONFIG_VIDEO_OMAP3
 #define LCD_BPP                LCD_COLOR16
 
-- 
1.8.3.2