I've discovered that the woods off the corner of my property give me a good straight run where I could run a 150' or so beverage pointed directly at EU.
The difficulty is...it's not my property there, but a wooded area connected to a neighboring apple farm. It isn't being used, but it's still a little shady to run an antenna there. I was thinking of getting something like this https://www.dxengineering.com/parts/svp-sv-bog and running a wire into the woods. The difficulty is that these seem to want to be terminated at the far end, but I've seen people talking about using them unterminated. Given this isn't my land, I'd rather not drive a ground rod on the far end - we also have pretty rock soil and getting the rods into the ground is a bear. -Can I only have a ground rod at the near (feed) end and just leave the far end unterminated? -If I ran a longer wire, but zig zagged it how would that affect the receive ability? I figure a black length of wire laying on the ground will go basically un-noticed and be out of the way. Any thoughts? Sean Waite, WA1TE _________________ Topband Reflector Archives - http://www.contesting.com/_topband