Date: Fri, 11 Apr 2025 14:41:30 +0300 From: Valery Ushakov <u...@stderr.spb.ru> Message-ID: <z_j_6hejmvmyo...@snips.stderr.spb.ru>
| If the wired down device cannot be attached its wildcard siblings will | not use that number. Not just that number, but any lower number either. Wildcards start numbering at the next higher number after the biggest wired down number. kre