Author: mav
Date: Thu Jan 31 22:22:22 2013
New Revision: 246179
URL: http://svnweb.freebsd.org/changeset/base/246179

Log:
  MFC r245363:
  Improve support for disabled disks. If disabled disk disconnected and then
  reconnected back, leave it as disabled. If new disk inserted instead of
  disabled, rebuild it and leave as enabled.

Modified:
  stable/8/sys/geom/raid/g_raid.c
  stable/8/sys/geom/raid/md_intel.c
Directory Properties:
  stable/8/sys/   (props changed)
  stable/8/sys/geom/   (props changed)

Modified: stable/8/sys/geom/raid/g_raid.c
==============================================================================
--- stable/8/sys/geom/raid/g_raid.c     Thu Jan 31 22:21:39 2013        
(r246178)
+++ stable/8/sys/geom/raid/g_raid.c     Thu Jan 31 22:22:22 2013        
(r246179)
@@ -535,7 +535,7 @@ g_raid_report_disk_state(struct g_raid_d
        if (disk->d_consumer == NULL)
                return;
        if (disk->d_state == G_RAID_DISK_S_DISABLED) {
-               ;
+               s = G_STATE_ACTIVE; /* XXX */
        } else if (disk->d_state == G_RAID_DISK_S_FAILED ||
            disk->d_state == G_RAID_DISK_S_STALE_FAILED) {
                s = G_STATE_FAILED;

Modified: stable/8/sys/geom/raid/md_intel.c
==============================================================================
--- stable/8/sys/geom/raid/md_intel.c   Thu Jan 31 22:21:39 2013        
(r246178)
+++ stable/8/sys/geom/raid/md_intel.c   Thu Jan 31 22:22:22 2013        
(r246179)
@@ -787,13 +787,9 @@ g_raid_md_intel_start_disk(struct g_raid
        disk_pos = intel_meta_find_disk(meta, pd->pd_disk_meta.serial);
        if (disk_pos < 0) {
                G_RAID_DEBUG1(1, sc, "Unknown, probably new or stale disk");
-               /* Disabled disk is useless for us. */
-               if (pd->pd_disk_meta.flags & INTEL_F_DISABLED) {
-                       g_raid_change_disk_state(disk, G_RAID_DISK_S_DISABLED);
-                       return (0);
-               }
                /* Failed stale disk is useless for us. */
-               if (pd->pd_disk_meta.flags & INTEL_F_FAILED) {
+               if ((pd->pd_disk_meta.flags & INTEL_F_FAILED) &&
+                   !(pd->pd_disk_meta.flags & INTEL_F_DISABLED)) {
                        g_raid_change_disk_state(disk, 
G_RAID_DISK_S_STALE_FAILED);
                        return (0);
                }
@@ -884,10 +880,11 @@ nofit:
        }
 
        /* Welcome the new disk. */
-       if (resurrection)
-               g_raid_change_disk_state(disk, G_RAID_DISK_S_ACTIVE);
-       else if (meta->disk[disk_pos].flags & INTEL_F_DISABLED)
+       if ((meta->disk[disk_pos].flags & INTEL_F_DISABLED) &&
+           !(pd->pd_disk_meta.flags & INTEL_F_SPARE))
                g_raid_change_disk_state(disk, G_RAID_DISK_S_DISABLED);
+       else if (resurrection)
+               g_raid_change_disk_state(disk, G_RAID_DISK_S_ACTIVE);
        else if (meta->disk[disk_pos].flags & INTEL_F_FAILED)
                g_raid_change_disk_state(disk, G_RAID_DISK_S_FAILED);
        else if (meta->disk[disk_pos].flags & INTEL_F_SPARE)
@@ -910,14 +907,15 @@ nofit:
                                migr_global = 0;
                }
 
-               if (resurrection) {
-                       /* Stale disk, almost same as new. */
-                       g_raid_change_subdisk_state(sd,
-                           G_RAID_SUBDISK_S_NEW);
-               } else if (meta->disk[disk_pos].flags & INTEL_F_DISABLED) {
+               if ((meta->disk[disk_pos].flags & INTEL_F_DISABLED) &&
+                   !(pd->pd_disk_meta.flags & INTEL_F_SPARE)) {
                        /* Disabled disk, useless. */
                        g_raid_change_subdisk_state(sd,
                            G_RAID_SUBDISK_S_NONE);
+               } else if (resurrection) {
+                       /* Stale disk, almost same as new. */
+                       g_raid_change_subdisk_state(sd,
+                           G_RAID_SUBDISK_S_NEW);
                } else if (meta->disk[disk_pos].flags & INTEL_F_FAILED) {
                        /* Failed disk, almost useless. */
                        g_raid_change_subdisk_state(sd,
@@ -1021,7 +1019,8 @@ nofit:
        /* Update status of our need for spare. */
        if (mdi->mdio_started) {
                mdi->mdio_incomplete =
-                   (g_raid_ndisks(sc, G_RAID_DISK_S_ACTIVE) <
+                   (g_raid_ndisks(sc, G_RAID_DISK_S_ACTIVE) +
+                    g_raid_ndisks(sc, G_RAID_DISK_S_DISABLED) <
                     meta->total_disks);
        }
 
@@ -1053,7 +1052,8 @@ g_raid_md_intel_refill(struct g_raid_sof
        update = 0;
        do {
                /* Make sure we miss anything. */
-               na = g_raid_ndisks(sc, G_RAID_DISK_S_ACTIVE);
+               na = g_raid_ndisks(sc, G_RAID_DISK_S_ACTIVE) +
+                   g_raid_ndisks(sc, G_RAID_DISK_S_DISABLED);
                if (na == meta->total_disks)
                        break;
 
@@ -1065,7 +1065,8 @@ g_raid_md_intel_refill(struct g_raid_sof
                TAILQ_FOREACH(disk, &sc->sc_disks, d_next) {
                        if (disk->d_state == G_RAID_DISK_S_STALE) {
                                update += g_raid_md_intel_start_disk(disk);
-                               if (disk->d_state == G_RAID_DISK_S_ACTIVE)
+                               if (disk->d_state == G_RAID_DISK_S_ACTIVE ||
+                                   disk->d_state == G_RAID_DISK_S_DISABLED)
                                        break;
                        }
                }
@@ -1089,8 +1090,8 @@ g_raid_md_intel_refill(struct g_raid_sof
        }
 
        /* Update status of our need for spare. */
-       mdi->mdio_incomplete = (g_raid_ndisks(sc, G_RAID_DISK_S_ACTIVE) <
-           meta->total_disks);
+       mdi->mdio_incomplete = (g_raid_ndisks(sc, G_RAID_DISK_S_ACTIVE) +
+           g_raid_ndisks(sc, G_RAID_DISK_S_DISABLED) < meta->total_disks);
 
        /* Request retaste hoping to find spare. */
        if (mdi->mdio_incomplete) {
@@ -2242,7 +2243,8 @@ g_raid_md_write_intel(struct g_raid_md_o
                        pd->pd_disk_meta.flags = INTEL_F_FAILED |
                            INTEL_F_ASSIGNED | INTEL_F_DISABLED;
                } else {
-                       pd->pd_disk_meta.flags = INTEL_F_ASSIGNED;
+                       if (!(pd->pd_disk_meta.flags & INTEL_F_DISABLED))
+                               pd->pd_disk_meta.flags = INTEL_F_ASSIGNED;
                        if (pd->pd_disk_meta.id != 0xffffffff) {
                                pd->pd_disk_meta.id = 0xffffffff;
                                len = strlen(pd->pd_disk_meta.serial);
_______________________________________________
svn-src-all@freebsd.org mailing list
http://lists.freebsd.org/mailman/listinfo/svn-src-all
To unsubscribe, send any mail to "svn-src-all-unsubscr...@freebsd.org"

Reply via email to